Air Exhaust Ventilation - Graco ChemSafe 307 Instructions - Parts Manual

Air-operatedo diaphragm pump
Table of Contents

Advertisement

Air
Air Exhaust
Air
Exhaust Ventilation
Exhaust
Ventilation
Ventilation
If pumping toxic fluids, you must vent the exhaust
away from people, animals, food handling areas,
and all sources of ignition. Follow all applicable
codes.
NOTE:
NOTE:
NOTE: Do not restrict the air exhaust port. Excessive
exhaust restriction can cause erratic pump operation.
A
Air supply line
J
Air inlet port (not visible)
K
Exhaust port
334793E
Tel: 866-777-6060
Fax: 866-777-6383
To provide
provide a a a remote
To
To
provide
1. Use Kit 17F610 (NPT) or 17F611 (BSPT), sold
separately.
2. Remove the muffler (U) from the pump air
exhaust port (K).
3. Install the adaptor from the kit.
4. Install a grounded air exhaust hose (S). If a hose
longer than 10 ft. (3 m) is required, use a larger
diameter hose. Avoid sharp bends or kinks in
the hose.
5. Place a container (T) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
S
T
U
Springer Pumps, LLC
remote exhaust:
exhaust:
remote
exhaust:
Grounded air exhaust hose
Container for remote air exhaust
Muffler
Website: www.springerpumps.com
Int'l: +001 267 404 2910
Installation
11