Repair
8. Align the outlet manifold (8) on the assembly with
the outlet port facing in the correct direction for
your application.
22
Springer Pumps, LLC
Telford, PA 18969
9. Align the outlet manifold retainers (11) on the
10. On each screw (29), place two belleville washers
11. Turn the pump over and insert a ball retainer
12. Align the inlet manifold (10) on the assembly.
13. Align the inlet manifold retainers (12) on the inlet
14. On each screw (29), place two belleville washers
15. Follow
16. Replace all bolt covers (37).
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
outlet manifold (8).
(27), with the rounded side of first washer toward
the screw head and the rounded side of the
second washer away, then a flat #12 washer
(26). Thread each screw assembly through an
outlet manifold retainer (11) and into the fluid
cover (6), and tighten by hand for now.
(20), check ball (22), d-ring (21), and o-ring (17)
into the inlet side of each fluid cover (6).
Use the placement of dowel pins (23) to orient
the manifold so the inlet port is facing the correct
direction for your application.
manifold (10).
(27), with the rounded side of first washer toward
the screw head and the rounded side of the
second washer away, then a flat #12 washer
(26). Thread each screw assembly through an
inlet manifold retainer (11) and into the fluid cover
(6) and tighten by hand for now.
Torque Instructions, page
23.
334794B
shop.springerpumps.com
info@springerpumps.com