Procedure
Step 1 Log in to the APM. Choose Configuration > Single Configuration and select an ePico3801 to
be maintained. Then, click Configure to enter the configuration window.
Step 2 Choose Terminal Parameter > WIRELESS > Configuration in the navigation tree to set the
handover parameters.
1.
2.
3.
Step 3 After the parameter setting is complete, click Apply. A system message is displayed, indicating
whether the parameter setting is successful.
----End
5.4.6 Modifying the ePico3801 Parameters Related to the Handover
to 2G Macro Cells
This chapter describes how to modify the ePico3801 parameters manually to implement the
handover to the 2G macro cells. In normal cases, these parameters of the ePico3801 are set
automatically. No manual setting is required.
Prerequisite
l
l
Procedure
Step 1 Log in to the APM. Choose Configuration > Single Configuration and select an ePico3801 to
be maintained. Then, click Configure to enter the configuration window.
Step 2 Choose Terminal Parameter > WIRELESS > Configuration > INTERRATHOCOV in the
navigation tree to set the inter-RAT handover algorithm parameters, such as the thresholds,
hysteresis, and trigger delay time of the active set and the inter-RAT system.
Step 3 After the parameter setting is complete, click Apply. A system message is displayed, indicating
whether the parameter setting is successful.
----End

5.5 Adjusting the Transport Network

This chapter describes how to adjust the transport network of the ePico3801.
Issue 01 (2009–09–23)
Choose INTRAFREQHO to set the ePico3801-oriented intra-frequency handover
measurement algorithm parameters.
Choose INTERFREQHOCOV to set the ePico3801-oriented inter-frequency handover
measurement algorithm (based on coverage) parameters.
Choose HOCOMM to set common handover parameters.
NOTE
For details about how to set the parameters, see Help in the corresponding command configuration window.
The 2G macro neighboring cells have been configured automatically or manually.
You have logged in to the AP Manager (APM). The login account belongs to the
Administrator or Operators group.
NOTE
For details about how to set the parameters, see Help in the corresponding configuration window.