Everbilt CSP010 Use And Care Manual

Everbilt CSP010 Use And Care Manual

Condensate pump

Advertisement

SKU#1000026611
Model#CSP010
USE AND CARE GUIDE
CONDENSATE PUMP
Questions, problems, missing parts? Before returning to the store call
Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-844-241-5521
HOMEDEPOT.COM
Rev. 05/20/17
THANK YOU
We appreciate the trust and confidence you have placed in Everbilt through the purchase of this condensate pump. We strive to continually create
quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing Everbilt!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSP010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Everbilt CSP010

  • Page 1 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this condensate pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ............2 TOOLS REQUIRED ............. 4 Performance ..............2 PACKAGE CONTENTS ............4 Safety Information ............2 SPECIFICATIONS .............. 4 Warranty ................. 3 Operation ............... 5 Pre-Operation ..............4 Troubleshooting ............7 APPLICATION ..............4 Performance GPH of Water @ Total Feet Of Lift Max.
  • Page 3: Warranty

    Safety Information (continued) IMPORTANT: Before using the pump, check the tubing for CAUTION: Know the pump and its applications, holes or excess wear, which could cause leaks, and ensure limitations, and potential hazards. the tubing is not kinked or making sharp angles. Straight tubing allows the pump to move the greatest amount of water quickly, and also check that all tubing connections are CAUTION: Follow all local electrical and safety codes,...
  • Page 4: Pre-Operation

    Pre-Operation APPLICATION This non-submersible utility pump is designed for condensate removal applications. Pump water only with this pump.  This pump has not been tested or approved for use in swimming pools or in salt-water marine areas. This pump is not designed to ...
  • Page 5: Operation

    Operation NOTE: This unit is non-submersible. The pump should not be installed in a manner that will subject it to flooding, splashing or spraying. Connecting the air conditioning Mounting the pump condensate drain tubing The tank has two slots (1) provided to mount the unit. The slots Ensure the tubing to the pump intake is fastened securely so that ...
  • Page 6 Operation (continued) SAFETY SWITCH The safety switch is designed to activate an alarm (sold separately) or to cut off power in the event of high water in the condensate reservoir. To control a thermostatic circuit the COM and NO connections from the safety switch are to be wired in series with the low voltage thermostat circuit to shut down the heating/AC circuit.
  • Page 7: Troubleshooting

    1. Check valve should be hand-tightened. around check valve. 2. Damaged O-ring. 2. Contact Everbilt customer service for replacement. My air conditioner is 1. Check safety switch on condensate pump to 1. Check blockage in drainage tube, or replace condensate pump.