5-5.
Rear Plate Assembly
Preparation
1.
Remove the upper plate assembly. (Refer to
2.
Remove the bottom plate. (Refer to
Procedure
1.
Disconnect the two harnesses from the two connectors (CN11, CN512) on the BD-44 board.
2.
Remove the harness from the PW harness clamp and the clamp.
Bottom side
CN512
(BD-44 board)
Harness
PW harness clamp
3.
Remove the screw to detach the t-clamp bracket.
4.
Disconnect the fine-wire coaxial cable from the connector on the IF-1234 board (in case of ODS-D77U) or the
connector on the FC-116 board (in case of ODS-D77F).
[ODS-D77U]
T-clamp bracket
IF-1234
board
CN2
ODS-D77U/ODS-D77F
"5-1. Upper Plate
"5-4. Bottom
Plate")
CN11
(BD-44 board)
Clamp
PSW2.6 x 5.8
Fine-wire coaxial cable
Assembly")
Harness (D77U only)
[ODS-D77F]
T-clamp bracket
FC-116
board
Fine-wire coaxial cable
PSW2.6 x 5.8
CN2
5-7