Main
Sub
Error
Code
Code
Logger
595
○
597
○
5A5
○
5A7
○
5B5
○
5B7
○
5C5
○
5C7
○
695
○
6A5
○
6B5
○
6C5
○
2-1-7.
Error 95
When a peripheral device IC error is detected, one of the following error codes is displayed.
Main
Sub
Error
Code
Code
Logger
95
50D
○
50E
○
50F
○
510
○
ODS-D77U/ODS-D77F
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
○
0.25 sec.
Communication between Disc Drive LSI (IC100: BD-44 board)
and BRIDGE (IC700: BD-44 board) cannot be established dur-
ing startup.
○
0.25 sec.
Failure in Disc Drive LSI (IC100: BD-44 board) firmware up-
grade was detected during startup.
○
0.25 sec.
Communication between Disc Drive LSI (IC200: BD-44 board)
and BRIDGE (IC700: BD-44 board) cannot be established dur-
ing startup.
○
0.25 sec.
Failure in Disc Drive LSI (IC200: BD-44 board) firmware up-
grade was detected during startup.
○
0.25 sec.
Communication between Disc Drive LSI (IC300: BD-44 board)
and BRIDGE (IC700: BD-44 board) cannot be established dur-
ing startup.
○
0.25 sec.
Failure in Disc Drive LSI (IC300: BD-44 board) firmware up-
grade was detected during startup.
○
0.25 sec.
Communication between Disc Drive LSI (IC400: BD-44 board)
and BRIDGE (IC700: BD-44 board) cannot be established dur-
ing startup.
○
0.25 sec.
Failure in Disc Drive LSI (IC400: BD-44 board) firmware up-
grade was detected during startup.
○
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
UM4 (IC100: BD-44 board) cannot be established during start-
up. Or, failure in UM4 (IC100: BD-44 board) firmware upgrade
was detected during startup.
○
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
UM4 (IC200: BD-44 board) cannot be established during start-
up. Or, failure in UM4 (IC200: BD-44 board) firmware upgrade
was detected during startup.
○
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
UM4 (IC300: BD-44 board) cannot be established during start-
up. Or, failure in UM4 (IC300: BD-44 board) firmware upgrade
was detected during startup.
○
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
UM4 (IC400: BD-44 board) cannot be established during start-
up. Or, failure in UM4 (IC400: BD-44 board) firmware upgrade
was detected during startup.
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
○
0.25 sec.
BRIDGE (IC700: BD-44 board) temperature alarm was detec-
ted.
○
1 sec.
BRIDGE (IC700: BD-44 board) temperature exceeded 80 °C.
○
1 sec.
The BRIDGE (IC700: BD-44 board) detected an abnormal stop
of the fan (FAN1).
○
0.25 sec.
No data can be read from the SPI-EEPROM (IC709: BD-44
board).
Continued
2-8