Error 6X; Error 91 - Sony ODS-D77U Service Manual

Optical disc archive drive unit
Hide thumbs Also See for ODS-D77U:
Table of Contents

Advertisement

Main
Sub
Error
Code
Code
Logger
008
009
200
201
2-1-5.

Error 6X

When a failure is detected relating to a startup operation or relating to an adjustment before writing, one of the following
error codes is displayed.
Main
Sub
Error
Code
Code
Logger
61
000
6F
E00
E03
E80
E83
F00
F03
F80
F83
2-1-6.

Error 91

When an operation error of the CPU or DSP is detected, one of the following error codes is displayed.
Main
Sub
Error
Code
Code
Logger
91
515
557
565
567
ODS-D77U/ODS-D77F
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
0.25 sec.
A comparison error between the disc BCA code in the cartridge
memory and the actual media BCA code was detected.
0.25 sec.
A comparison error between the media type in the cartridge
memory and the actual media type was detected.
1 sec.
A TDMA area error was detected during write-back to the re-
cording disc or formatting.
1 sec.
A disc error was detected during finalizing of the recording disc.
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
1 sec.
Depletion of OPC area in the disc was detected.
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0A.
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0A.
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0B.
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0B.
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1A.
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1A.
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1B.
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1B.
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
0.25 sec.
Communication with the SATA host is disabled.
0.25 sec.
A firmware alarm or startup of the recovery firmware was de-
tected.
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
FPGA (IC700: BD-44 board) cannot be established during start-
up.
0.25 sec.
Failure in SYCPU (IC720: BD-44 board) firmware upgrade was
detected during startup.
Continued
2-7