2 2

Getting Started

A. Design and Installation Considerations
Consideration must be given to:
-
Safety
-
Convenience
-
Traffic flow
-
Chimney and chimney connector required
It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation. If you are not
using an existing chimney, place the appliance where there
will be a clear passage for a factory-built listed chimney
through the ceiling and roof.
We recommend that a qualified building inspector and
your insurance company representative review your plans
before and after installation.
If this appliance is in an area where children may be near
it is recommended that you purchase a decorative barrier
to go in front of the appliance. Remember to always keep
children away while it is operating and do not let anyone
operate this appliance unless they are familiar with these
operating instructions.
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult insurance carrier, local building, fire officials
or authorities having jurisdiction about restrictions,
installation inspection, and permits.
!
Asphyxiation Risk.
Do NOT connect this appliance to a
chimney flue servicing another appliance.
Do NOT connect to any air distribution
duct or system.
May allow flue gases to enter the house.
4
CAUTION
WARNING
Quadrafire • Expedition II AU Install Manual_Rev B • 2020 - ___ • 09/20
NOTICE: Hearth & Home Technologies assumes no
responsibility for the improper performance of
the appliance system caused by:
Inadequate draft due to environmental conditions
Down drafts
Tight sealing construction of the structure
Mechanical exhausting devices
Over drafting caused by excessive chimney heights
Ideal performance is with height of chimney between
14-16 feet (4.26-4.88m) measured from the base of
the appliance.
B. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each floor of your
home to ensure your safety. They should be located away
from the heating appliance and close to the sleeping
areas. Follow the smoke detector manufacturer's
placement and installation instructions, and be sure to
maintain regularly.
2. A conveniently located Class A fire extinguisher to
contend with small fires resulting from burning embers.
3. A CO detector should be installed in the room with
the appliance.
4. A practiced evacuation plan, consisting of at least two
escape routes.
5. A plan to deal with a chimney fire as follows:
In the event of a chimney fire:
a. Evacuate the house immediately
b. Notify fire department.