Download Print this page
Emerson Rosemount 3051HT Quick Start Manual

Emerson Rosemount 3051HT Quick Start Manual

Hygienic pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 3051HT:

Advertisement

Quick Links

Quick Start Guide
00825-0300-4091, Rev BA
June 2020
Rosemount
3051HT Hygienic Pressure
Transmitter
®
with PROFIBUS
PA Protocol

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rosemount 3051HT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson Rosemount 3051HT

  • Page 1 Quick Start Guide 00825-0300-4091, Rev BA June 2020 ™ Rosemount 3051HT Hygienic Pressure Transmitter ® with PROFIBUS PA Protocol...
  • Page 2 Quick Start Guide June 2020 Safety messages NOTICE This guide provides basic guidelines for the Rosemount 3051HT Transmitter. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations. WARNING Explosions could result in death or serious injury.
  • Page 3 June 2020 Quick Start Guide CAUTION Keep the vent path free of any obstruction, including but not limited to paint, dust, and lubrication by mounting the device so the process can drain away. Interfering or blocking the atmospheric reference port will cause the device to output erroneous pressure values.
  • Page 4 Quick Start Guide June 2020 Emerson.com/Rosemount...
  • Page 5 Transmitter must not be securely mounted or clamped in place when changing transmitter orientation. Conduit entry orientation When installing a Rosemount 3051HT, it is recommended installing so a conduit entry faces downward or parallel to the ground to maximize drainability when cleaning.
  • Page 6 Default security is off ( ). Setting the simulate switch The security switch can be enabled or disabled in the software. Procedure 1. If the transmitter is installed, secure the loop, and remove power. 2. Remove the housing cover opposite the field terminal side. Emerson.com/Rosemount...
  • Page 7 June 2020 Quick Start Guide WARNING Explosions could result in death or serious injury. In an explosion-proof/flameproof installation, do not remove the transmitter covers when power is applied to the unit. 3. Slide the security switch into the preferred position. 4.
  • Page 8 5. Plug and seal unused conduit connections. 6. Reattach the transmitter covers. a) The covers must only be capable of being released or removed with the aid of a tool to comply with applicable ordinary locations requirements. Figure 1-3: Wiring Aluminum Polished 316 SST Emerson.com/Rosemount...
  • Page 9 June 2020 Quick Start Guide A. Minimize distance B. Trim shield and insulate C. Protective grounding terminal (do not ground cable shield at the transmitter) D. Insulate shield E. Connect shield back to the power supply ground 1.4.1 Signal ground wiring Do not run signal wiring in conduit or open trays with power wiring, or near heavy electrical equipment.
  • Page 10 3. Replace the housing cover. It is recommended that the cover be tightened until there is no gap between the cover and the housing. 4. Plug and seal unused conduit connections. Note The Rosemount 3051HT polished 316 SST housing only provides ground termination inside the terminal compartment. Emerson.com/Rosemount...
  • Page 11 June 2020 Quick Start Guide Basic configuration Configuration tasks The transmitter can be configured via either the local operator interface ™ (LOI) - option code M4, or via a Class 2 Master (DD or DTM based). The two ® basic configuration tasks for the PROFIBUS PA Pressure transmitter are: Procedure 1.
  • Page 12 Figure 2-1: LOI Menu Class 2 Master ® The Rosemount 3051 PROFIBUS DD and DTM files are available at Emerson.com or by contacting your local salesperson. See Table 2-2 steps to configure the transmitter for Pressure measurement. See the Rosemount 3051...
  • Page 13 3051 specific (rmt4444.gsd) or Profile 3.02 Generic (pa139700.gsd). These files can be found on Emerson.com or Profibus.com. Configuration host (class 2) The appropriate DD or DTM file must be installed in the configuration host. These files can be found at Emerson.com. Quick Start Guide...
  • Page 14 A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine...
  • Page 15 June 2020 Quick Start Guide Standards: ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2. No.157-92, CSA Std. C22.2 No. 213 - M1987 Markings: Intrinsically Safe Class I, Division 1 Groups A, B, C, D when connected in accordance with Rosemount drawing 03031-1024, Temperature Code T4;...
  • Page 16 0 µF Inductance L 0 mH 0 mH Special Conditions for Safe Use (X): 1. If the equipment is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by Emerson.com/Rosemount...
  • Page 17 EPL Ga. Additional certifications ® All Rosemount 3051HT transmitters with the following connections are 3-A approved and labeled: T32: 1½-in. Tri Clamp T42: 2-in. Tri Clamp...
  • Page 18 Quick Start Guide June 2020 Figure 3-1: Rosemount 3051HT Declaration of Conformity Emerson.com/Rosemount...
  • Page 19 June 2020 Quick Start Guide Figure 3-2: Rosemount 3051HT Declaration of Conformity Quick Start Guide...
  • Page 20 Quick Start Guide June 2020 Figure 3-3: Rosemount 3051HT Declaration of Conformity Emerson.com/Rosemount...
  • Page 21 June 2020 Quick Start Guide China RoHS Quick Start Guide...
  • Page 22 Quick Start Guide June 2020 Emerson.com/Rosemount...
  • Page 23 June 2020 Quick Start Guide Quick Start Guide...
  • Page 24 The Emerson logo is a Twitter.com/Rosemount_News trademark and service mark of Emerson Electric Facebook.com/Rosemount Co. Rosemount is a mark of one of the Emerson Youtube.com/user/ family of companies. All other marks are the RosemountMeasurement property of their respective owners.