Maintenance and care
6.1.1
Mechanical
SERVICE INTERVAL
First inspection after
25 operating hours
All 50 operating hours
Minimum 1x per year
(at rough conditions shorten the
interval)
6.2
Repairs
Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.
6.3
Safety procedures
•
It is the contractor's responsibility to ensure that the device is checked by an expert in periods of
max. 1 year and all recognized errors are removed (→ see DGUV regulation 1-54 and DGUV norm 100-500).
•
The corresponding legal regulations and the regulations of the declaration of conformity must be
observed!
•
The expert inspection can also be done by the manufacturer Probst GmbH.
Contact us at:
service@probst-handling.com
•
We recommend affixing the inspection sticker "„Sachkundigenprüfung / Expert inspection" in a clearly
visible place (order no.: 2904.0056+Tüv sticker with year number) after the inspection has been done.
4400.0184
Maintenance work
•
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
•
Tighten all screws and connections (take care that the tightening torques according to
the property class of the screws are observed).
•
Check all existing safety elements (such as linchpins) for perfect function and replace
defective safety elements. → 1)
•
Check all joints, bolts, guidance's and gears for correct function, if necessary adjust or
replace it.
•
Check all grippers (if available) for signs of wear.
•
Grease all slidings (if available) when the device is in opened position with a spatula.
•
Grease all grease nipples (if available) with a grease gun.
•
Check of all the suspension parts, bolts and straps. Check for corrosion and safety by an
expert.
1)