Intratone Visio Installation And Connection

Telephone intercom with scrolling name-display

Advertisement

Quick Links

INSTALLATION AND CONNECTION OF
THE VISIO PANEL KEY SAFE
The Visio call panel + with built-in Key Safe (ref.: EEN-PVICBV3) combines a "traditional"
use of Visio call panels from the INTRATONE range with the ability to store mechanical
keys securely inside a Key Safe for access to technical services premises.
It must be connected to the following "real-time" central units:
2 to 4 doors (ref.: EEN-CEN12)
1 door
Three opening methods enable access to the keys stored inside the key safe:
By using an authorised badge
By typing in a specific code
By calling the administrator using the call panel, who then opens the key safe using
a key on his/her telephone
Product description:
The Visio telephone intercom with scrolling name-display consists of:
A 12-key keypad and backlit LCD screen
Two scrolling keys and one call button
A proximity reader.
A miniature camera for use in video calls
Built-in speech synthesiser: "Call in progress"; "Door open", etc.
The key safe:
Three hooks for hanging keys 12 cm long
An audible confirmation sounds on powered opening of the key safe
Ability to manage key-monitoring alerts
It is managed remotely and in real time from the following website:
the ʺmanagement website" tabʺ.
LCD display
Scrolling keys
Call buttons
Keys on Keypad
Proximity reader
EN-V233 – 5004 – AA Installation and use of call panel + key safe EEN-PVIBCV3

GENERAL POINTS

(ref.: EEN-CIC12)
Key safe
A single key safe per central unit
www.intratone.com
+
+
in
Built-in
wall box
Screws
X 8
Page 1 / 12

Advertisement

Table of Contents
loading

Summary of Contents for Intratone Visio

  • Page 1: General Points

    The Visio call panel + with built-in Key Safe (ref.: EEN-PVICBV3) combines a "traditional" use of Visio call panels from the INTRATONE range with the ability to store mechanical keys securely inside a Key Safe for access to technical services premises.
  • Page 2: Table Of Contents

    CONTENTS GENERAL POINTS -----------------------------------------1 CONTENTS ---------------------------------------------------2 DIMENSIONS AND ASSEMBLY ------------------------3 --------------------------------------------------------- 3 IMENSIONS OF CALL PANEL ----------------------------------------------------- 4 UILT IN WALL BOX DIMENSIONS CABLING ------------------------------------------------------5 ---------------------------------------------------------------------- 5 ENERAL POINTS AUDIO ---------------------------------------------------- 5 OR USE IN CALLS ONLY VIDEO ------------------------------------------------------------ 5 OR USE IN CALLS CENARIO OF CONNECTING AN ENTRANCE GATE WITH THE...
  • Page 3: Dimensions And Assembly

    DIMENSIONS AND ASSEMBLY IMENSIONS OF CALL PANEL EN-V233 – 5004 – AA Installation and use of call panel + key safe EEN-PVIBCV3 Page 3 / 12...
  • Page 4: B) Built - In Wall Box Dimensions

    UILT IN WALL BOX DIMENSIONS EN-V233 – 5004 – AA Installation and use of call panel + key safe EEN-PVIBCV3 Page 4 / 12...
  • Page 5: Cabling

    CABLING See EEN-CIC12 guide: V233 - 5002 - XX See EEN-CEN12 guide: V233-5001-XX Power supply: 12 / 24 V – 2 to 4 A Not supplied EEN- EEN- EEN-CIC12 EEN-CEN12 + - D+ D- + - D+ D- A+A- ENERAL POINTS POWER SUPPLY : The central unit supplies power to the call panel via the + / - terminals.
  • Page 6: D) Scenario Of Connecting An Entrance Gate With The Central Units

    CENARIO OF CONNECTING AN ENTRANCE GATE WITH THE TYPES OF CENTRAL UNITS Connections in red refer to video (V+ / V-) Connections in black refer to (+ / - and D+ / D- and A+ / A-) CENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING It is mandatory to use an EEN-CEN12 central unit with, in this example, an extension board.
  • Page 7: Equipment Configuration

    EQUIPMENT CONFIGURATION ENERAL POINTS INTRATONE call panels are mainly configured using the following website: www.intratone.com in the ʺmanagement website" tab. Nevertheless, some settings can be changed on-site: - Configuration of the push button. - Configuration of the door-opening time. - Panel sound volume...
  • Page 8: C) Configuration With An Post-Fitting Check

    EEN-CIC12 ONFIGURATION WITH AN NTRACODE CENTRAL UNIT Exit from menus or Go into menus or Make a Return to scrolling menu selection Validation "Save changes" Entering numbers How do I enter settings mode? o Check that the welcome message is scrolling on the LCD screen o Press the ֠...
  • Page 9: D) O N The Panel

    POST-FITTING CHECK Before leaving the fitting, the following points should be checked: N THE ANEL Display shows the welcome message Check that the keypad keys (0, 1, 2 9, * and #) work. Procedure: o Press #; the display shows "Call number" o The numeric keys must be displayed correctly o Finish using the * key;...
  • Page 10: Diagnosis In The Event Of A Fault

    The resident cannot see - Incorrect V+ / V- cabling - Check V+ / V- cabling the visitor on his/her - Call panel not a Visio - Install an EEN-PICVIV1 call panel telephone panel instead of an EEN-PIC - The unit is not a 3G unit...
  • Page 11: Certificate Of Conformity

    CERTIFICATE OF CONFORMITY TANDARDS EC standards: The central unit complies with the R&TTE Directive 1999/5/EC: electrical safety standard EN 60950(2001) applied, EMC standard EN 301 489-3 (2002) applied, radio standard EN 300 330-2 (2001) applied The central unit complies with telephone network standards TS-103 021 and TR- 103 000.

Table of Contents