MSA OptimAir MM 2K User Instructions
MSA OptimAir MM 2K User Instructions

MSA OptimAir MM 2K User Instructions

Mask-mounted powered air-purifying respirator

Advertisement

Quick Links

OptimAir
'
USER
S INSTRUCTIONS
Mask-Mounted
Powered Air-Purifying Respirator
THIS MANUAL, INCLUDING THE WARNINGS AND CAUTIONS
INSIDE, MUST BE READ AND FOLLOWED CAREFULLY BY ALL PER-
SONS WHO USE OR MAINTAIN THIS PRODUCT, INCLUDING THOSE
WHO HAVE ANY RESPONSIBILITY INVOLVING ITS SELECTION,
APPLICATION, SERVICE, OR REPAIR. THIS RESPIRATOR WILL PER-
FORM AS DESIGNED ONLY IF USED AND MAINTAINED ACCORD-
ING TO THE INSTRUCTIONS. OTHERWISE IT COULD FAIL TO PER-
FORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT
COULD SUSTAIN SERIOUS PERSONAL INJURY OR DEATH.
The warranties made by MSA with respect to the product are
voided if the product is not installed, used, and serviced in
accordance with the instructions in this manual. We encourage our
customers to write or call for a demonstration of this equipment
prior to use or for any additional information relative to use or
repairs. Call 1-800-MSA-2222 during regular working hours.
See Approval Matrix Part No. 818105 for NIOSH Approvals and
Limitations.
TAL 0110 (L) Rev. 8
© MSA 2010
MM 2K
®
Prnt. Spec. 10000005389(F)
Mat. 10020949
Doc. 10000007610

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OptimAir MM 2K and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MSA OptimAir MM 2K

  • Page 1 FORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT COULD SUSTAIN SERIOUS PERSONAL INJURY OR DEATH. The warranties made by MSA with respect to the product are voided if the product is not installed, used, and serviced in accordance with the instructions in this manual. We encourage our...
  • Page 2: Table Of Contents

    Test Method for OptimAir MM 2K ........
  • Page 3: Introduction

    (See OSHA LIMITATIONS regulations, Title 29 CFR, Part 1910.134, Sub-part I par. 1910.134 The OptimAir MM 2K with OptiFilter (b) (1)). Type HE filter cartridge, or Type HE par- ticulate filter, are approved as high effi- 2. This respirator will perform as...
  • Page 4 INTRODUCTION ture of particulates that are present NIOSH REL, ACGIH TLV, etc.) is simultaneously or alternately not known or when it is below against one particulate then anoth- the odor threshold or any other er (using the same filter) if the mix- established warning level for the ture meets the following condi- contaminant.
  • Page 5 INTRODUCTION biological agents and help reduce • Do NOT remove respirator in con- the risk for influenza infection taminated areas. The outer sur- during a pandemic, but will NOT face of the respirator MUST be eliminate the risk of exposure, treated as if it is contaminated at all times.
  • Page 6 NOTES TAL 0110 (L) Rev. 8 - 10020949...
  • Page 7: Description

    NOT immediately dan- charger. gerous to life or health (IDLH). The replaceable filter cartridge which The OptimAir MM 2K is used with the traps the particulate contaminant is at Facepiece, which is available in small, least 99.97% efficient against 0.3 micron DOP aerosol.
  • Page 8 + . . . • American Industrial Hygiene Association (AIHA) Only use these equations if the contam- Contact MSA at 1-800-MSA-2222 for inants present are actually mixed. Some information. substances do not mix and may be present separately, for example, in Exposure Limits for Mixtures pockets or at different levels.
  • Page 9: Charging The Battery Pack

    CHARGING THE BATTERY PACK UNPACKING & INSPECTION or if air output is reduced, the entire motor-blower must be replaced. The OptimAir MM 2K consists of the following components: motor-blower CHARGING THE BATTERY PACK battery pack support belt The battery pack must be fully charged charger before the respirator is first used.
  • Page 10 CHARGING THE BATTERY PACK 2. Push the plug into the female con- The charger uses one LED. When the nector and turn the ring _ turn to battery is charging, the LED will be secure it. Red. When the LED is Green the bat- 3.
  • Page 11: Respirator Assembly

    MSA respira- tors. Check that the inhalation check valve and spider gasket are in the 5. Thread the filter facepiece inhalation housing.
  • Page 12 NOTES TAL 0110 (L) Rev. 8 - 10020949...
  • Page 13: Using The Respirator

    USING THE RESPIRATOR DONNING THE FACEPIECE Do not wear this respirator unless you have received training in its use and have read all of the instructions. Cover lenses are installed on the out- side of the facepiece lens to protect Do not use this respirator in an area the plastic surface.
  • Page 14 USING THE RESPIRATOR DONNING THE ADVANTAGE 3000 b. Move the slide away from the MODEL 3100 SINGLE PORT OR lens ring to allow the strap to ADVANTAGE 4000 MODEL 4100 slide through the lens ring con- SINGLLE PORT WITH RUBBER nection.
  • Page 15 USING THE RESPIRATOR 3. Pull the harness over head with 5. Tighten the two loop, pull harness down to the back lower straps first of the head until plastic cradle lies by pulling them flat on back of head. straight back, not 4.
  • Page 16 USING THE RESPIRATOR 2. Inhale so that the piece seal must be tested before facepiece collaps- each use. DO NOT USE A FACE- es against your PIECE THAT DOES NOT SEAL. face. Hold your breath for 10 sec- onds. The face- CONNECTING THE BATTERY PACK piece should remain collapsed.
  • Page 17 USING THE RESPIRATOR DECONTAMINATION 5. Grip the facepiece by the inhalation housing. The OptimAir MM 2K may be used in some applications which may require decontamination of personal and respi- 6. Pull the facepiece ratory equipment before the respirator out, then up over may be removed.
  • Page 18 NOTES TAL 0110 (L) Rev. 8 - 10020949...
  • Page 19: Maintaining The Respirator

    With the filter removed, contamina- tion from the surfaces of the respira- tain the respirator. Use only genuine MSA parts. Do not make repairs or tor can be drawn into the facepiece. design modifications other than as Failure to follow this warning can...
  • Page 20 Remove the nosecup (if used). Confidence Plus™ Germicidal Cleaner This will facilitate cleaning the (P/N 10009971) from MSA is recom- inside of the facepiece. mended. Refer to the label for use d. Remove the exhalation valve instructions. A solution as effective as cover.
  • Page 21 Lower temperatures will decrease capacity and operating time will be reduced. The other OptimAir MM 2K components can Alcohol should not be used as a ger- be stored at temperatures of 0°F to micide, because it may deteriorate 120°F.
  • Page 22 NOTES TAL 0110 (L) Rev. 8 - 10020949...
  • Page 23: Test Method For Optimair Mm 2K

    MM 2K. A Digital Multimeter is required. The test method should only be used if Testing the Charger: any one of the OptimAir MM 2K PAPR The MM 2K comes standard with a dual- components (charger, battery pack, or rate smart-charger. This charger has a motor-blower) is not functioning properly.
  • Page 24 TEST METHOD FOR OPTIMAIR MM 2K TESTING THE BATTERY PACK: Testing the Open Circuit Voltage across the Switch: The electrical function of the battery 1. Set the multimeter to measure volt- pack can be measured by using a mul- age.
  • Page 25 TEST METHOD FOR OPTIMAIR MM 2K Resistance" will result in an indication 2. Using a good battery pack as deter- of charge failure status by the charger. mined by the previous tests, fully In this case, the battery pack is defec- charge the battery until a full charge tive and should be replaced.
  • Page 26: Chart

    CHART Charge Battery Pack Successful Charge Charge - Failure - Red Green LED Flashing LED Change Charge OCV Switch Fail Battery and Failure - Red Test Recharge Flashing LED Successful Replace Fail Charge - Recharge Charger Circuit Test Green LED Replace Thermistor Fail...
  • Page 27: Accessories

    Prescription 2. Starting at the lenses can be obtained locally or top, stretch and through MSA. push the rubber ring of the nose- cup under the ADJUSTING THE SPECTACLES plastic retainer ring of the speak- 1.
  • Page 28 ACCESSORIES 4. Grasp the outside of the cartridge, PARTS twist and push on the spark cover. The spark cover will snap in place. Confidence Plus Cleaner 5. To remove the spark cover, gently (P/N 100009971) squeeze the outside of the cover, twist, an dpull the spark cover off.
  • Page 29 TAL 0110 (L) Rev. 8 - 10020949...
  • Page 30 804820 804831 10116528 Door, Component Housing, ClearCommand 495188 495189 804805 804804 10051290 804810 805011 TAL 0110 (L) Rev. 8 - 10020949...
  • Page 31 TAL 0110 (L) Rev. 8 - 10020949...

Table of Contents