4.Function Set-up by Use
4-1.Setting STEP ANGLE SELECT switch
(1)
Set the step angle required by the STEP SEL switch [SA,SB,SC].
●Relationship between the STEP SEL switch and the step angle.
STEP SEL switch
SC
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from six different
types of step angles.
1/
Divisions
SB
SA
ON
ON
1/1
ON
OFF
1/2
OFF
ON
1/4
OFF
OFF
1/10
ON
ON
1/20
ON
OFF
1/40
OFF
ON
OFF
OFF
CAUTION
Step angle(°)
0.72°motor
0.72
0.36
0.18
0.072
0.036
0.018
Sub adjustment
Sub adjustment
-13-
Instructions Manual
(Factory setting)
(Not available)
(Not available)
ADB-5F41EL