10.Specifications
10-1.General Specifications
Supply Power
Motor output
current
Input Signal
Output Signal
Functions of
Operating
Sections
Overheat alarm
Operating
Ambient
Temperature
Operating
Ambient
Humidity
Storing
Temperature
Storing
Humidity
Altitude
Atmosphere
Withstanding
Vibration
Insulation
resistance
Exterior
Dimensions
Weight
Input voltage range is DC+24V±10%.
*1
Use a power supply that provides sufficient input current.
*2
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
● Rated input current 〔DRIVE I.SEL ⇒ D1=ON set up〕
at DRIVE
● Rated input current 〔HOLD I.SEL ⇒ H1=OFF set up〕
at HOLD
●Drive pulse input
●Motor excitation
stop input
●Drive pulse input
●Alarm clear signal input
●Extend functions signal
●Encoder signal input
●Alarm signal output
●Feature expansion signal output
●Step angle selection
●DRIVE CURRENT selection
●HOLD CURRENT selection
●Extend functions selection
●Overheat alarm
(ALM LED)
0℃ ~ +40℃
(No freezing allowed.)
80%RH or less
(No condensation allowed.)
-10℃ ~ +55℃
(No freezing allowed.)
80%RH or less
(No condensation allowed.)
Up to 1000m above sea level
Indoor (Exposure to direct sun is not allowed.)
Without any explosive, corrosive or inflammable gas, oil mist,
or dust.
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
DC connector - signal connector - Frame
(Each other)
H
W
D
77 ×
85 ×
28 (mm)
0.1kg
DC+24V: 2.1A
*2
DC+24V: 0.3A
DRIVE I.SEL OFF:0.75A/phase(typical)
DRIVE I.SEL ON :1.40A/phase(typical)
HOLD I.SEL OFF:Approx. 40% of DRIVE CURRENT
HOLD I.SEL ON :Approx. 50% of DRIVE CURRENT
(CW,CCW)
(ACLR)
(IN)
(A phase,B
phase,Z phase)
(ALM)
(OUT)
(STEP SEL)
(DRIVE I.SEL)
(HOLD I.SEL)
(OP SEL)
-28-
ADB-5F41EL
Instructions Manual
Photo-coupler input
Photo-coupler input
Photo-coupler input
Photo-coupler input
O/C output
O/C output
DC500V 100MΩ or more
R1
Need help?
Do you have a question about the ADB-5F41EL and is the answer not in the manual?