Specification

16. Specification

16.1 Energy consumption data

Product datasheet: DHW cylinder to regulation (EU) no. 812/2013
Manufacturer
Designation
Energy efficiency class
Standby losses
Cylinder capacity

16.2 Data table

Hydraulic data
Nominal capacity, DHW cylinder
Nominal capacity, buffer cylinder
Surface area, indirect coil
Capacity, indirect coil
External available pressure differential, circulation pump/heat pump at 1.0 m³/h
External available pressure differential, circulation pump/heat pump at 1.5 m³/h
External available pressure differential, circulation pump/heat pump at 2.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.5 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 2.0 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 1.0 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 1.5 m³/h
External available pressure differential, circulation pump / heating circuit 2 (optional) at 2.0 m³/h
Application limits
Max. permissible pressure, DHW cylinder
Test pressure, DHW cylinder
Max. flow rate
Max. permissible pressure, buffer cylinder
Test pressure, buffer cylinder
Max. permissible temperature
Max. permissible temperature, primary side
Heating water quality requirements
Water hardness
pH value (with aluminium fittings)
pH value (without aluminium fittings)
Conductivity (softening)
Conductivity (desalination)
Chloride
Oxygen 8-12 weeks after filling (softening)
Oxygen 8-12 weeks after filling (desalination)
Power consumption
Max. power consumption, charging pump
Max. power consumption, circulation pump on the heating side
Energy data
Standby energy consumption/24 h at 65 °C
Energy efficiency class
Electrical data
Frequency
Versions
IP rating
Dimensions
Height
Width
Depth
Height when tilted
www.stiebel-eltron.com
HSBC 300 cool
W
l
236686
STIEBEL ELTRON
HSBC 300 cool
B
61
291
HSBC 300 cool
l
l
l
hPa
hPa
hPa
hPa
hPa
hPa
hPa
hPa
hPa
MPa
MPa
l/min
MPa
MPa
°C
°C
°dH
8.0-10.0
μS/cm
μS/cm
mg/l
mg/l
mg/l
W
W
kWh
Hz
mm
mm
mm
mm
HSBC 300 cool | HSBC 300 L cool |
HSBC 300 L cool
238826
STIEBEL ELTRON
HSBC 300 L cool
B
61
291
HSBC 300 L cool
236686
238826
270
270
100
100
3.3
3.3
21
21
656
527
210
725
725
663
663
444
444
665
665
518
518
189
189
1.0
1.0
1.5
1.5
25
25
0.3
0.3
0.45
0.45
95
95
75
75
≤3
≤3
8.0-8.5
8.0-8.5
8.0-10.0
<1000
<1000
20-100
20-100
<30
<30
<0.02
<0.02
<0.1
<0.1
72
72
72
1.6
1.6
B
B
50
50
IP20
IP20
1918
1918
680
680
910
910
2123
2123
57

Advertisement