Installation and Power Requirements

Disintegrator Location

The Model 250 can be located in an office area within 6 feet of a wall receptacle with a dedicated 20-
amp line. It is recommended that there be unit be two to three inches between the rear of the unit
and the wall.

Electrical Wiring (See Page 12 for Electrical Diagram)

A.
The Model 250 includes an appropriate power cord and 20-amp male plug. The Model 250
is activated by a front mounted ON/OFF toggle switch.
B.
The 1-gallon capacity vacuum unit is supplied with a plug for 115V (7.3 amp) or 3-gallon
220V (4.8 amp) to suit the customer's order requirements. The vacuum plugs directly into
the receptacle supplied in the unit's base.
C.
The Model 250 has been wired to your original order specifications. The motor supplied
operates on single phase voltage (115V or 220V).
D.
Note: Motors are normally dual voltages, 115/230V, but can only be operated at the
specific voltage as wired at the factory, if voltage change is required in the field contact the
factory for proper instructions.
E.
If for any reason the Model 250 is rotating in the wrong direction, disconnect the power
(unplug), and remove the metal plate on the motor and change the leads as shown on
the plate diagram.
F.
Electrical schematics available in PDF on request.

Power Requirements

115 Volt/1-Phase/60 Cycle requires 18 amps
230 Volt/1-Phase/60 Cycle requires 9.6 amps
230 Volt/1-Phase/50 Cycle requires 11.5 amps