13.1) Environment Correction

The standard condition of rated power output:
Altitude:0m
o
Ambient temperature:25 C
Relative humidity:30%
Factor of environment correction:
Ambient temperature℃
Altitude(m)
25
30
0
1
0.98
500
0.93
0.91
1000
0.87
0.85
2000
0.75
0.73
3000
0.64
0.62
4000
0.54
0.52
NOTE: Relative humidity 60% correction factorC-
Example:
Rated power(P )3.5kVA generator(Altitude:
1000m) Ambient temperature: 35℃ ,Relative
35
40
45
humidity: 80%
0.96
0.93
0.90
0.89
0.87
0.84
0.82
0.80
0.78
0.71
0.69
0.66
0.60
0.58
0.56
0.50
0.48
0.46
0.01;
Relative humidity 80% correction
factorC -0.02;
Relative humidity 90% correction factorC-
0.03;
Relative humidity 100% correctionfactorC-
0.04;
N
P=Pn*(C-0.02)=3.5*(0.82-0.02)=2.8 kVA