1.8 General Technical Data
Protection and features
•
Electronic thermal motor protection against overload.
•
Temperature monitoring of the heatsink ensures that the adjustable frequency drive trips in case of overtem-
perature.
•
The adjustable frequency drive is protected against short-circuits between motor terminals U, V, W.
•
When a motor phase is missing, the adjustable frequency drive trips and issues an alarm.
•
When a line phase is missing, the adjustable frequency drive trips or issues a warning (depending on the load).
•
Monitoring of the intermediate circuit voltage ensures that the adjustable frequency drive trips when the
intermediate circuit voltage is too low or too high.
•
The adjustable frequency drive is protected against ground faults on motor terminals U, V, W.
Line power supply (L1/L, L2, L3/N)
Supply voltage
Supply voltage
Supply frequency
Max. temporary imbalance between line phases
True Power Factor
Displacement Power Factor (cosφ) near unity
Switching on input supply L1/L, L2, L3/N (power-ups)
Environment according to EN60664-1
The unit is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 240/480 V
maximum.
Motor output (U, V, W)
Output voltage
Output frequency
Switching on output
Ramp times
Cable lengths and cross-sections
Max. motor cable length, shielded/armored (EMC-compatible installation)
Max. motor cable length, non-shielded/unarmored
Max. cross-section to motor, line power*
Connection to load sharing/brake (M1, M2, M3)
Max. cross-section to load sharing/brake (M4, M5)
Maximum cross-section to control terminals, rigid wire
Maximum cross-section to control terminals, flexible cable
Maximum cross-section to control terminals, cable with enclosed core
Minimum cross-section to control terminals
* See chapter 1.7 Specifications for more information!
18
Quick Guide
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
200–240 V ±10%
380–480 V ±10%
3.0% of rated supply voltage
≥0.4 nominal at rated load
maximum 2 times/min.
Overvoltage category III/pollution degree 2
0–100% of supply voltage
plus
0–200 Hz (VVC
), 0–400 Hz (u/f)
0.25 in [6.3 mm] insulated Faston plugs
16 mm
2
1.5 mm
/16 AWG (2x0.75 mm
1 mm
0.5 mm
0.00039 in
50/60 Hz
(>0.98)
Unlimited
0.05–3,600 s
50 ft [15 m]
164 ft [50 m]
2
/6 AWG
2
)
2
/18 AWG
2
/20 AWG
2
2
[0.25 mm
]
MG02B922