Quick Guide
1
1

1.8 General Technical Data

Protection and features
Electronic thermal motor protection against overload.
Temperature monitoring of the heatsink ensures that the adjustable frequency drive trips in case of overtem-
perature.
The adjustable frequency drive is protected against short-circuits between motor terminals U, V, W.
When a motor phase is missing, the adjustable frequency drive trips and issues an alarm.
When a line phase is missing, the adjustable frequency drive trips or issues a warning (depending on the load).
Monitoring of the intermediate circuit voltage ensures that the adjustable frequency drive trips when the
intermediate circuit voltage is too low or too high.
The adjustable frequency drive is protected against ground faults on motor terminals U, V, W.
Line power supply (L1/L, L2, L3/N)
Supply voltage
Supply voltage
Supply frequency
Max. temporary imbalance between line phases
True Power Factor
Displacement Power Factor (cosφ) near unity
Switching on input supply L1/L, L2, L3/N (power-ups)
Environment according to EN60664-1
The unit is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 240/480 V
maximum.
Motor output (U, V, W)
Output voltage
Output frequency
Switching on output
Ramp times
Cable lengths and cross-sections
Max. motor cable length, shielded/armored (EMC-compatible installation)
Max. motor cable length, non-shielded/unarmored
Max. cross-section to motor, line power*
Connection to load sharing/brake (M1, M2, M3)
Max. cross-section to load sharing/brake (M4, M5)
Maximum cross-section to control terminals, rigid wire
Maximum cross-section to control terminals, flexible cable
Maximum cross-section to control terminals, cable with enclosed core
Minimum cross-section to control terminals
* See chapter 1.7 Specifications for more information!
18
Quick Guide
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
200–240 V ±10%
380–480 V ±10%
3.0% of rated supply voltage
≥0.4 nominal at rated load
maximum 2 times/min.
Overvoltage category III/pollution degree 2
0–100% of supply voltage
plus
0–200 Hz (VVC
), 0–400 Hz (u/f)
0.25 in [6.3 mm] insulated Faston plugs
16 mm
2
1.5 mm
/16 AWG (2x0.75 mm
1 mm
0.5 mm
0.00039 in
50/60 Hz
(>0.98)
Unlimited
0.05–3,600 s
50 ft [15 m]
164 ft [50 m]
2
/6 AWG
2
)
2
/18 AWG
2
/20 AWG
2
2
[0.25 mm
]
MG02B922