Technical data • Individual components
Model number
Interfaces
POWERLINK
Quantity
Transmission
Type
Design
Transfer rate
Cable length
Electrical characteristics
Power consumption
Operating conditions
EN 61131 pollution degree
Environmental conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical characteristics
Weight
1)
Yes, although applies only if all components installed within the complete system have this certification and the complete system itself carries the corresponding
mark.
2)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
3.4.3.3.1 POWERLINK 1 interface - Pinout
The POWERLINK 1 interface on the system unit is referred to as IF1.
Cabling
Cable length
Status LED
Green
Link LED
Yellow
Link (POWERLINK net-
work connection available)
1)
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by
the particular operating system.
3.4.3.3.2 POWERLINK 2 interface - Pinout
The POWERLINK 2 interface on the system unit is referred to as IFx.
Cabling
Cable length
Status LED
Green
Link LED
Yellow
Link (POWERLINK net-
work connection available)
1)
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by
the particular operating system.
100
Table 97: 5ACCIF01.FPLK-000 - Technical data
POWERLINK 1 - IF1
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
Off
See Status/Error LED.
On
Off
Activity (blinking - da-
ta transfer in progress)
Table 98: 5ACCIF01.FPLK-000 - POWERLINK 1 interface
POWERLINK 2 - IFx
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
Off
See Status/Error LED.
On
Off
Activity (blinking - da-
ta transfer in progress)
Table 99: 5ACCIF01.FPLK-000 - POWERLINK 2 interface
5ACCIF01.FPLK-000
1 (integrated 2-port hub)
100BASE-TX
Type 4, redundant
Shielded RJ45
100 Mbit/s
Max. 100 m between two stations (segment length)
1.75 W
Pollution degree 2
-20 to 55°C
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
25 g
1)
1
Link LED
1)
1
Link LED
Panel PC 2100 swing arm user's manual V1.12
2)
RJ45, female
Status LED
RJ45, female
Status LED
Need help?
Do you have a question about the 2100 and is the answer not in the manual?