Download Print this page

Program Settings - Nibe POOL 11 Installation Instructions Manual

For fighter 1120/1140/1220/1240/1250

Advertisement

Available languages

Available languages

8. Connect Actuator Shuttle valve SV4 as follows:
- Black cable (230v signal) to spring terminal –X6:1
- Brown cable (fixed phase) to spring terminal –X6:2
- Blue cable (zero) to spring terminal –X6:3
9. Connect circulation pump P8 as follows:
- Blue cable (zero) to spring terminal –X6:3
- Yellow/green cable (earth cable) to spring terminal
–X6:4
- Brown cable (phase) to spring terminal –X6:5
Temperature sensor installation
Install the temperature sensor with cable ties with the
heat conducting paste and aluminium tape.
Then insulate with supplied insulation tape.
Note!
Sensor and communication cables must not
be placed near power cables.

Program settings

FIGHTER 1120/1140
Program version 1.08 and earlier
Select service in menu 8.1.1 to gain access to all the
menus.
Activate pool control in menu 9.2.10 by selecting
"ON". This activates the external circulation pump
and shows the pool setting menus. The pool sensor
must be connected to terminal X1:12-13 otherwise
a sensor alarm is displayed for the pool sensor.
Select the desired pool temperature in menu 1.11.1,
this temperature determines when pool heating is
stopped.
Select the desired connection difference in menu
1.11.2, this is the difference between the value in
menu 1.11.1 and when pool heating starts.
Select the desired pool charging time in menu
1.11.3, this is how long pool heating is permitted to
run. The value can be set between 5 and 60 min-
utes. When pool charging has started, it runs for at
least the time selected in this menu even if a heating
requirement arises.
Program version 1.09 and later
Select service in menu 8.1.1 to gain access to all the
menus.
Activate pool control in menu 9.2.10 by selecting
"ON". This activates the external circulation pump
and shows the pool setting menus. The pool sensor
must be connected to terminal X1:12-13 otherwise
a sensor alarm is displayed for the pool sensor.
Activate pool control in menu 8.4.4 by selecting
"ON". The allows the heat pump to heat the pool.
Select "Off" in menu 8.4.4 to prevent pool heating,
e.g. winter time.
Select the desired pool temperature in menu 8.4.1,
this temperature determines when pool heating is
stopped.
Select the desired connection difference in menu
8.4.2, this is the difference between the value in
menu 8.4.1 and when pool heating starts.
Select the desired pool charging time in menu 8.4.3,
this is how long pool heating is permitted to run.
The value is adjustable between 5 and 60 minutes.
When pool charging has started, it runs for at least
the time selected in this menu even if a heating re-
quirement arises.
POOL 11
GB
27

Advertisement

loading