Download Print this page
Nibe ECS 40 Installer Manual
Nibe ECS 40 Installer Manual

Nibe ECS 40 Installer Manual

Extra climate system for nibe f1145, f1155, f1245, f1255, f1345, f370, f470, f750, vvm310, vvm320, vvm500, smo40
Hide thumbs Also See for ECS 40:

Advertisement

Quick Links

ECS 40/ECS 41
Installatörshandbok Extra Klimatsystem
SE
för NIBE F1145, F1155, F1245, F1255, F1345,
F370, F470, F750, VVM310, VVM320, VVM500,
SMO40
Installer manual Extra climate system
GB
for NIBE F1145, F1155, F1245, F1255, F1345,
F370, F470, F750, VVM310, VVM320, VVM500,
SMO40
Installateurhandbuch Extra mischgruppe
DE
für NIBE F1145, F1155, F1245, F1255, F1345,
F370, F470, F750, VVM310, VVM320, VVM500,
SMO40
Asentajan käsikirja Lisälämmitysjärjestelmä
FI
NIBE F1145, F1155, F1245, F1255, F1345,
F370, F470, F750, VVM310, VVM320, VVM500,
SMO40
IHB 1426-2
231401

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECS 40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe ECS 40

  • Page 1 ECS 40/ECS 41 Installatörshandbok Extra Klimatsystem för NIBE F1145, F1155, F1245, F1255, F1345, F370, F470, F750, VVM310, VVM320, VVM500, SMO40 Installer manual Extra climate system for NIBE F1145, F1155, F1245, F1255, F1345, F370, F470, F750, VVM310, VVM320, VVM500, SMO40 Installateurhandbuch Extra mischgruppe für NIBE F1145, F1155, F1245, F1255, F1345,...
  • Page 2 Heating pipe paste Designations in component locations according to Aluminium tape standard IEC 81346-1 and 81346-2. Insulation tape Replacement gasket Temperature sensor Room sensor Pipe with straight coupling* * This is only used when connecting to NIBE F370 or F470...
  • Page 3 Pipe connections General Heat pump/ Flow pipe When connecting extra climate systems, they must be indoor module connected so that they have a lower working temper- ature than the climate system 1. Circulation pump and mixing valve The extra circulation pump (GP20) is positioned in the extra climate system according to the outline diagram.
  • Page 4 Pump and pressure drop diagrams, ECS 40 Available pressure Tillgängligt tryck Speed III Speed I Speed II Flow Flöde 800 1000 1200 1400 1600 Pump and pressure drop diagrams, ECS 41 Available pressure Tillgängligt tryck Speed II Speed I Speed III Flow Flöde...
  • Page 5 Non-return valve RM13 EB101 Heat pump system (slave) EB101 Heat pump EP21 Climate system 2 (ECS 40/ECS 41 AA25 Unit box Flow temperature sensor, extra climate system Return line sensor, extra climate system GP20 Circulation pump, extra climate system QN25...
  • Page 6 Outline diagram F1145/F1155 with ECS 40/ECS 41 and up to three extra climate systems -EP23 -AA25 -BT2 -GP20 -BT3 -QN25 -EP22 -AA25 -BT2 -GP20 -BT3 -QN25 -EP21 -AA25 -BT2 -GP20 -BT3 -QN25 -EB100-BT1 -QM12 -FL2 -CM2 -CM1 -QM42 -QM31 -XL15...
  • Page 7 Outline diagram F1345 with ECS 40/ECS 41 and up to three extra climate systems -EP23 -AA25 -BT2 -GP20 -BT3 -QN25 -EP22 -AA25 -BT2 -GP20 -BT3 -QN25 -EP21 -AA25 -BT2 -GP20 -BT3 -EB1 -QN25 -FL10 -CM5 -EB1 -CP20 -EB100-BT25 -GP10 -GP18...
  • Page 8 -AA25 -BT2 -GP20 -EB100 -BT3 -QN25 -EB100 -EP21 -AA25 -BT2 -GP20 -BT3 -QN25 Outline diagram VVM310 with ECS 40/ECS 41 and up to three extra climate systems -EP23 -AA25 -BT2 -GP20 -BT3 -QN25 -EP22 -AA25 -BT2 -GP20 -BT3 -QN25 -EP21...
  • Page 9 Outline diagram VVM320 with ECS 40/ECS 41 and up to three extra climate systems -EP23 -AA25 -BT2 -GP20 -BT3 -QN25 -EP22 -AA25 -BT2 -GP20 -BT3 -QN25 -EP21 -AA25 -BT2 -GP20 -BT3 -QN25 -EB15 -EB101 -QM41 -QM40 -QN50 -FL10 Outline diagram VVM500 with ECS 40/ECS 41 and up to three extra climate systems...
  • Page 10 Outline diagram SMO40 with ECS 40/ECS 41 and up to three extra climate systems -EP23 -AA25 -BT2 -GP20 -BT3 -EB1 -QN25 -AA25 -EP22 -FL10 -AA25 -BT2 -CM5 -GP20 -EB1 -BT3 -QN25 -QM42 -QM43 -RN11 -EP21 -AA25 -BT2 -GP20 -BT3 -QN25...
  • Page 11 Electrical installation and wiring must be car- ried out in accordance with the stipulations in force. The heat pump/indoor module must not be powered when installing ECS 40/ECS 41. The electrical circuit diagram is at the end of this In- staller handbook. Connecting communication...
  • Page 12 Air/water heat pumps Control module This accessory contains an accessory board (AA5) that Indoor modules is connected to (AA5-X4) on control module. This accessory contains an accessory card (AA5) that If several accessories are to be connected or are already must be connected directly to the indoor module on installed, the following instructions must be followed.
  • Page 13 Exhaust air heat pumps This accessory contains an accessory board (AA5) that must be connected directly to the heat pump on the input board (terminal block AA3-X4) in F370/F470/F750 If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory board must be connected directly to the input board's terminal block (AA3-X4) in the heat pump.
  • Page 14 Connection of sensors and external adjust- Connection of the mixing valve motor ment (QN25) Use cable type LiYY, EKKX or similar. For location of Connect the mixing valve motor (QN25) to AA5-X9:6 terminal blocks, see Component positions page 18. (230 V, open), AA5-X9:5 (N) and AA5-X9:4 (230 V, close).
  • Page 15 Select: "climate system 2" for climate system 2, "climate system 3" for climate system 3, and "climate system 4" for climate system 4. Control voltage 230 V 1) Applies to NIBE F1145, F1155, F1245, F1255, F370, F470 and value F750. Connection valve (Ø mm) Menu 5.2.4 - accessories Activating/deactivating of accessories.