7.2 Wiring the Terminals
Wire the Intelligent Tap to the IO-Link Master Unit.
The IO-Link Master Unit uses a screwless clamping terminal block. So, ferrules that are attached
to the twisted wires can be easily wired simply by inserting into the terminal holes of the terminal
block.
Refer to the NX-series IO-Link Master Unit User's Manual for information on the wiring and
ferrules to connect to the screwless clamping terminal block.
Connect the Intelligent Tap to port 1 of
1
the IO-Link Master Unit.
Note: For details on connecting the
safety light curtain and the
Intelligent Tap, refer to 3-2.
Connection in the Safety Light
Curtain/Multi-Beam Safety
Sensor F3SG-
PG

No. Z405).
Insert the ferrule straight into the
2
terminal hole.
It is not necessary to press a flat-
blade screwdriver into the release
hole.
After making the connection, make
3
sure that the ferrule is securely
connected to the terminal block.
SR
/F3SG-
User's Manual (Cat.
7 IO-Link Connection
Intelligent Tap
(F39-SGIT-IL3)
Black
White
Brown
When the IO-Link Master
Unit is connected
Blue
Brown
Black
White
Blue
Photoelectric
IO-Link
sensor
Master Unit
Ferrules
IO-Link
Master Unit
Port 1
IO-Link Master Unit
NX-ILM400
12