ecomatController CR720S/CR721S
Control systems
7.2.2 Test standards and regulations
CR721S
Test standards and regulations
CE marking
E1 marking
Electrical tests
Climatic tests
Mechanical tests
ifm electronic gmbh ● Friedrichstraße 1 ● 45128 Essen
36
EN 61000-6-2
EN 61000-6-4
EN 61010
UN/ECE-R10
ISO 7637-2
EN 60068-2-30
EN 60068-2-78
EN 60068-2-52
ISO 16750-3
EN 60068-2-6
ISO 16750-3
We reserve the right to make technical alterations without prior notice!
Technical data
Electromagnetic compatibility (EMC)
Noise immunity
Electromagnetic compatibility (EMC)
Radiation of interference
Safety requirements for electrical equipment for
measurement, control and laboratory use
Radiation of interference
Immunity with 100 V/m
Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: IV; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: IV; function state A
Pulse 5, severity level: III; function state A
(data valid for the 24 V system)
Pulse 4, severity level: III; function state A
(data valid for the 12 V system)
Damp heat, cyclic
Upper temperature 55°C, number of cycles: 6
Damp heat, steady state
Test temperature 40°C / 93% RH
Test duration: 21 days
Salt spray test
Severity level 3 (vehicle)
Test VII; Vibration, random
Mounting location: vehicle body
Vibration, sinusoidal
10���500 Hz; 0�72 mm/10 g; 10 cycles/axis
Bump
30 g/6 ms; 24,000 shocks
CR721S / page 4
22 Nov� 2017
Need help?
Do you have a question about the ecomatController and is the answer not in the manual?