IFM ecomatController CR0708 Operating Instructions Manual

IFM ecomatController CR0708 Operating Instructions Manual

Advertisement

Quick Links

Operating instructions
GB
ecomatController
CR0708
CR0709
HW version: V3.0.0.x

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecomatController CR0708 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IFM ecomatController CR0708

  • Page 1 Operating instructions ecomatController CR0708 CR0709 HW version: V3.0.0.x...
  • Page 2: Table Of Contents

    CR0708 CR0709 Contents Preliminary note ............. Symbols used .
  • Page 3: Preliminary Note

    CR0708 CR0709 1 Preliminary note You will find instructions, technical data, approvals, accessories and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
  • Page 4: Safety Instructions

    CR0708 CR0709 2 Safety instructions The unit is not approved for safety-related tasks in the field of operator protection. • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. –...
  • Page 5: Intended Use

    If required, take appropriate EMC screening measures. • Controller for mobile machinery applications. • CODESYS V3.5 programming system (in a version approved by ifm). • For the supply of the controller (on-board system, PELV power supply): Electrical connection (Ò / 10) •...
  • Page 6: Items Supplied

    1 screw for the shield connection 4 protective covers 1 operating instructions CE Declaration of Conformity u In the event of incomplete or damaged items supplied, please contact ifm. Programming manual and software (firmware of the controller and programming environment) at www.ifm.com.
  • Page 7: Installation

    CR0708 CR0709 5 Installation 5.1 Installation location The following installation locations are permitted: • inside of the cabin • body • vehicle frame Installation on the motor/engine is not permitted. For non-mobile applications, the applicable directives are to be adhered to, taking into account the specified environmental conditions.
  • Page 8: Heat Dissipation

    CR0708 CR0709 u During installation and replacing the device, ensure that the pollution degree is 2 or better. Pollution degree 2 is a light, common contamination which can become conductive caused by occasional condensation or hand perspiration (DIN EN 60664-1). 5.3 Heat dissipation CAUTION The housing can heat up considerably.
  • Page 9 CR0708 CR0709 ATTENTION Contact corrosion between the mounting screws and the housing w Damage to the device u Do not use stainless steel screws or nickel-plated screws. u Use zinc-plated screws. u In very corrosive environments such as extremely salty air, use screws with surface finishing on a zinc/nickel basis with thick-film passivation and sealing.
  • Page 10: Electrical Connection

    The connection terminals may only be supplied with the signals indicated in the technical data / on the device label and only the approved accessories from ifm may be connected. Only connect the connector pins as shown in the pin layout. Unspecified connector pins remain unconnected.
  • Page 11: Shield Connection

    CR0708 CR0709 u During installation, place the connectors vertically so that the coupling nut will not damage the thread. u Observe the coding of the connectors during installation. If sockets in the device: u Tighten the cable plug using 1.3 ± 0.1 Nm. u Cover unused connections with protective covers.
  • Page 12: Laying Of The Supply And Signal Cables

    CR0708 CR0709 Connection Nominal value fuse Required triggering characteristics ≤ 120 s at max. 6.25 A fuse ≤ 120 s at max. 6.25 A fuse 15 A ≤ 15 A (only with CR0709) ≤ 15 A Inputs / input groups ≤...
  • Page 13: Gnd Connections

    CR0708 CR0709 WARNING Load dump and surge w Destruction of the device or deterioration of the function u Always connect VBB The CAN bus is internally protected against short circuit to VBB and GND. For CAN cables ≥ 30 m, ensure appropriate protection against surge (e. g. shielded cables). 6.5.1 GND connections u Connect the GND and GND...
  • Page 14: Resistor Inputs

    CR0708 CR0709 supply input input nn GND controller Shield Fig. 5: Connection of the analogue inputs (A), example CR0709 u Connect GND to GND of the signal source. Do not connect GND to other GND connections or the common GND star point. 6.7 Resistor inputs supply input...
  • Page 15: High-Side Digital Inputs (Cso)

    CR0708 CR0709 u Connect GND to GND of the signal source. Do not connect GND to other GND connections or the common GND star point. Do not connect resistor inputs to a VBB. 6.8 High-side digital inputs (CSO) supply input , FRQ input , FRQ nn GND...
  • Page 16: Analogue Outputs

    CR0708 CR0709 6.9 Analogue outputs supply Con. A A (0...10 V) load Con. A controller Shield Fig. 8: Connection of the analogue outputs (A), example CR0709 The controller can be connected to the following loads: • resistive loads The connected load must not exceed the maximum permissible values of the respective output (Ò Technical data).
  • Page 17: Digital / Pwm Outputs

    CR0708 CR0709 6.10 Digital / PWM outputs supply output load output load output load controller Shield Fig. 9: Connection of the high-side digital outputs (PWMH, BH), example CR0709 GND star point WARNING • common interruption of all GND power supply connections and simultaneously •...
  • Page 18: Digital / Pwm Outputs, H-Bridge

    CR0708 CR0709 6.11 Digital / PWM outputs, H-bridge supply load load load controller load Shield Fig. 10: Connection of the low-side digital outputs (PWML, BL), example CR0709 The controller can be connected to the following loads: • resistive loads • capacitive loads (adapt diagnostic settings to the load, see programming manual) •...
  • Page 19 CR0708 CR0709 supply 24 V sensor input output load sensor input output load sensor input output load controller Shield Fig. 11: Example connection to 24 V and 12 V power supply combined, example CR0709 The operation of the output groups is possible with different supply voltages. u VBB , VBB and VBB...
  • Page 20: Set-Up

    In addition to the CODESYS programming system, the following documents are required for programming and set-up of the device: • CODESYS V3.5 programming manual The manuals can be downloaded from the internet: www.ifm.com CODESYS online help: www.ifm.com (in the download space with registration)
  • Page 21: Maintenance, Repair And Disposal

    8 Maintenance, repair and disposal The unit is maintenance-free. u Contact ifm in case of malfunction. u Do not open the housing as the unit does not contain any components which can be maintained by the user. The unit must only be repaired by the manufacturer.

This manual is also suitable for:

Ecomatcontroller cr0709

Table of Contents