M320 Multiservice Edge Router Quick Start

Committing the Configuration

28
the local subnet. To access the management Ethernet port from a remote subnet,
you must add a static route to that subnet within the routing table.
[edit]
root# set routing-options static route remote-subnet next-hop destination-IP retain
no-readvertise
Configure the telnet service at the
7.
[edit]
root#set system services telnet
For a chassis with two Routing Engines, commit the configuration changes to both Routing
Engines. When you issue the
between both Routing Engines and committed on both Routing Engines simultaneously.
For a chassis with only one Routing Engine, use the
command.
commit synchronize
Display the configuration to verify that it is correct.
1.
[edit]
root@host# show
## Last changed: 2008-10-17 18:32:25 UTC
version 9.1R1.8;
groups {
re0 {
system {
host-name host-re0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.69.155/21;
}
}
}
}
}
re1 {
system {
host-name host-re1;
}
interfaces {
em0 {
unit 0 {
family inet {
address 192.168.70.72/21;
}
}
}
}
}
global;
[edit system services]
command, the configuration is shared
commit synchronize
commit
Copyright © 2016, Juniper Networks, Inc.