1. DESCRIPTION - USE

Device dedicated to guarantee service continuity.
Via the app "POWER ON" (available for free on Google Play and
Play Store), gives to the user information on the status of the
associated circuit (open/ closed/ tripped ...).
In case of unwanted tripping (temporarily electrical disturbances or
other external events) and if no permanent fault is detected: it sends
a notification to user in order to get an authorization to remotely
switch ON the associated device.
In case of permanent fault: the user will be informed about it without
having the possibility to remotely switch on the power, to guarantee
total security.
The associated circuit must be protected by a 1 module per pole
DX
RCCB or RCBO up to 63 A.
3
2. RANGE
. Cat. n° 4 149 54: Eliot Kit Stop&Go Connected, composed by:
Non-automatic resetting Stop and go (cat. no 4 149 54)
. During a "normal situation":
- It permanently checks the status of the installation.
- It gives remotely a series of information to the user: circuit
open/closed, manually open/closed, ...
. Following an "unwanted tripping" due to a non-permanent fault:
- It reports the information through the Smartphone app
- Allows the user to remotely switch it ON
- In case of recurrent non-permanent faults, the Stop&Go will not
allow some remote command
. Following an "unwanted tripping" due to a permanent fault (earth
leakage or short circuit):
- It reports the information through the Smartphone app
- It does not allow the use to remotely switch-On the device and
advises to contact an electrician to check the installation.
. Technology: DC electric motor with permanent magnets
. 2 modules (35,6 mm) width
. Rated Voltage & Frequency: 230 V ~ 50 / 60 Hz with standard
tolerances.
. Operating voltages:
Minimum (0,85 x Un): 195,5 V
Maximum (1,1 x Un): 253 V
Technical data sheet: F02465EN/01
(not delivered with the kit).
(see details on page 5)
Updated: 28/03/2019
LEGRAND - BP30076
87045 LIMOGES CEDEX FRANCE
Telephone: 05 55 06 87 87 - Fax: 05 55 06 88 88
Cat. N°: 4 149 54
CONTENTS
1. Description - Use................................. 1
2. Product range ..................................... 1
3. Overall dimensions .............................. 1
4. Preparation - Connection .................... 2
5. General characteristics........................ 8
6. System architecture .......................... 12
9. Application messages ....................... 15
2. RANGE
(continued)
Wi-Fi interface module (cat. no 4 149 52)
To communicate with the Smartphone through a Wi-Fi Box
. 1 module (17,8 mm) width
. Supplied by the Power supply module via supply patch cord
. Equipped with a 1m length pre-cabled cable to connect with the
Stop&Go
Power Supplier Module for the Wi-Fi interface (cat. no 4 149 45)
. Primary voltage 95÷250 V~
. Secondary voltage 12 VDC 500 mA
. 1 module (17,8 mm) width
Supply patch cord:
. Allows to connect the Power supply module with the Wi-Fi interface
at the downstream through dedicated connectors.
. Length: 250 mm
Configuration & use:
. Must be used with the app "POWER ON"
. To be downloaded for free on Google Play or Play Store
All the configurations steps are explained in the app.
Note: This part can be done without any ADSL Wi-Fi box thanks to
the Wi-Fi module which allows to display its own network for this
step.

3. OVERALL DIMENSIONS

. Stop&Go
PAGE
Created: 06/10/2016
1/16

Advertisement

Table of Contents
loading

Summary of Contents for LEGRAND ELIOT Kit STOP&GO Connected

  • Page 1: Table Of Contents

    LEGRAND - BP30076 87045 LIMOGES CEDEX FRANCE Telephone: 05 55 06 87 87 – Fax: 05 55 06 88 88 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 CONTENTS PAGE 1. Description - Use......... 1 2. Product range ........1 3.
  • Page 2: Preparation - Connection

    ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 3. OVERALL DIMENSIONS 4. PREPARATION - CONNECTION (continued) . Wi-Fi interface module (already equipped with an external Half Fixing: Wave 2.4GHz Antenna With RP-SMA Connector): . On symmetric rail EN/IEC 60715 or DIN 35. Operating positions: .
  • Page 3 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued) List of possible associations: Wiring diagrams (continued) . DX 2P RCCBs . Power supply module: . DX 2P RCBOs (2 poles protected or P+N, 1 pole protected) protected by an MCB: Association Stop &Go - Protection device: protected by a Fuse holder:...
  • Page 4 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued) Recommended tools: Diagnostic procedure: . For the terminals of the Stop&Go: flat screwdriver 3,5 mm. . Once the kit assembly and the electrical connections have been .
  • Page 5 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued) Diagnostic procedure Diagnostic procedure (continued) (continued) 5. Test 1/3 - Set the AUTO/MAN selector to “MAN” (the Stop&Go 7. Test 3/3 - Simulation of a non-permanent fault and a remote LED flashes slowly in green) reclosing (continued)
  • Page 6 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued) On site information displayed by the Stop&Go: On site information displayed by the Stop&Go (continued) Stop&Go lockout: Device handle status (continued) .
  • Page 7 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued) On site information displayed by the Stop&Go Stop&Go signalling led: (continued) Details for “too recurrent” non-permanent faults: During its functioning, the Stop&Go memorises the numbers of faults and of remote/manual resetting operations.
  • Page 8: General Characteristics

    ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 4. PREPARATION - CONNECTION 4. PREPARATION - CONNECTION (continued) (continued): Wi-Fi module signalling led (continued): Power supply module signalling led: . Wi-Fi led: indicates the status of the Wi-Fi Network: . Indicates the status of operation of the supplier: Possible states: State Meaning...
  • Page 9 . Lateral side marking: by laser. - 230V~, 0,2A left side: Standard and programming information - 24 / 48V, 1A Standards right side Legrand address right side: cabling and traceability information Association scheme Wiring diagram Traceability information Supply connection with supply patch...
  • Page 10 . Rcc0 (non-operating rated resistance between the live parts): 1,5 Ω . Rcc (operating rated resistance between the live parts): 2,5 Ω . The Stop&Go device can be used in TT and TN earth systems Legrand address Impulse withstand voltage: . Uimp: 4 kV...
  • Page 11 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 5. GENERAL CHARACTERISTICS (continued) Plastic materials: . Self-extinguishing polycarbonate. . Heat and fire resistant according to IEC/EN 60695-2-12, glow-wire test at 960°C. . Classification UL 94 / IECEN 60695-11-10: V1 Ambient operating temperature: .
  • Page 12: System Architecture

    ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 6. SYSTEM ARCHITECTURE The Stop&Go ELIOT system requires that the Wi-Fi interface and the ADSL Wi-Fi box are always supplied. (not delivered with the kit) To do this can be implemented various system structures. .
  • Page 13: Conformities And Approvals

    . EN 62019, Electrical accessories – Circuit-breakers and similar equipment for household use - Auxiliary contact units (IEC 62019) . Legrand devices can be used under the conditions of use as defined by IEC / EN 60947. Environment respect – Compliance with CEE directives: .
  • Page 14: Auxiliaries And Accessories

    ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 8. AUXILIARIES AND ACCESSORIES Signalling auxiliaries: . Auxiliary contact (½ module – cat n° 4 062 58). . Fault signalling changeover switch (½ module – cat n° 4 062 60). . Auxiliary contact modifiable in default signal (½ module – cat n° 4 062 62). .
  • Page 15: Application Messages

    ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 9. APPLICATION MESSAGES . Hereunder are listed messages displayed by the Smartphone app, their meaning and possible actions to be done by the user Associated device is “OFF” and Stop& Go in AUTO mode. Remote reclosing command (closing of the circuit) allowed A non-permanent fault occurred Remote reclosing command (closing of the circuit) allowed...
  • Page 16 ELIOT Kit STOP&GO Connected Cat. N°: 4 149 54 9. APPLICATION MESSAGES (continued) . Hereunder are listed the messages furnished by the application, the meaning and possible actions done by the user Remote reclosing command (closing of the circuit) not-allowed Stop&Go is in MAN mode Put selector in “AUTO”...

This manual is also suitable for:

4 149 54

Table of Contents