Reference manual F
DOC.RM.BQC54.E Rev: 1
February, 2016
Table 4.1 Bettis Q-Series™ Resource Block (Continued)
Index
Name
No.
55
FD_FAIL_ALM
56
FD_OFFSPEC_ALM
57
FD_MAINT_ALM
58
FD_CHECK_ALM
59
FD_FAIL_PRI
60
FD_OFFSPEC_PRI
61
FD_MAINT_PRI
62
FD_CHECK_PRI
63
FD_SIMULATE
64
FD_RECOMMEN_ACT
65
FD_EXTENDED_ACTIVE
66
FD_EXTENDED_MAP
67
COMPATIBILITY_REV
68
HARDWARE_REVISION
69
SOFTWARE_REV
70
PD_TAG
71
DEV_STRING
72
DEV_OPTIONS
73
OUTPUT_BOARD_SN
74
FINAL_ASSY_NUM
75
DOWNLOAD_MODE
76
HEALTH_INDEX
Fieldbus Control module
OUNDATION
Description
This parameter is used primarily to broadcast a change in the
associated active conditions, which are not masked, for this alarm
category to a Host System.
This parameter allows the user to specify the priority of this alarm
category.
This parameter allows the conditions to be manually supplied when
simulation is enabled. When simulation is disabled both the diagnostic
simulate value and the diagnostic value track the actual conditions. The
simulation is enabled/disabled through a method and while simulation is
enabled the recommended action will show that simulation is active.
This parameter is a device enumerated summarization of the most
severe condition or conditions detected.
The DD help should describe by enumerated action, what should
be done to alleviate the condition or conditions. 0 is defined as Not
Initialized, 1 is defined as No Action Required, all others defined by
manuf.
An optional parameter or parameters to allow the user finer detail on
conditions causing an active condition in
the FD_*_ACTIVE parameters.
An optional parameter or parameters to allow the user finer control
on enabling conditions contributing to the conditions in FD_*_ACTIVE
parameters.
Compatibility Revision: This is used for device replacement and
indicates whether a previous rev can be replaced by the current device.
This is a new Foundation feature so previous revisions of the
Bettis Q-Series will not comply with the new device replacement rules.
Revision of hardware
Software revisions of FF card
Rev: xx-yy-zz (xx=major, yy= middle, zz=minor) Rev. date: dd-month-
yyyy
This parameter is the physical device tag of the field device.
Resource Block. Used to load new licensing into the device. The value
can be written but will always be read back with a value of 0
This parameter allows the operator access to the base record. When
the base record option is enabled, operator can write/read parameters
to/from the sensor board that are not available via the FF parameter list.
A method is used to enable/disable the parameter and a direct write is
not necessary.
Output Board Serial number is a unique 4 byte number of the FF card
for each device.
Final Assembly Number is a 4 byte static value that can be set by the
operator
Indicates whether the device is in run or download mode
Parameter representing the overall health of the device.
- 100 being perfect and 1 being non-functioning.
- No alerts -> 100
ADVISE_ACTIVE -> -10 per advice
MAINT_ACTIVE -> - 40 per advise
FAIL_ACTIVE -> = 10 (10 also lowest value)
Valid Range
Initial Value
Permission
0 to 15
0
ALARM
0 to 15
0
ALARM
0 to 15
0
ALARM
0 to 15
0
ALARM
Disabled
Read / Write
0
ALARM
Read only
4
Read only
0 to 255
N/A
Read only
N/A
N/A
Read only
Read only
Read / Write
0
Read / Write
Read only
0
Read / Write
Read only
10 to 100
100
Read only
Page 23