Table 4.1 Bettis Q-Series™ Resource Block
Index
Name
No.
1
ST_REV
2
TAG_DESC
3
STRATEGY
4
ALERT_KEY
5
MODE_BLK
6
BLOCK_ERR
7
RS_STATE
8
TEST_RW
9
DD_RESOURCE
10
MANUFAC_ID
11
DEV_TYPE
12
DEV_REV
13
DD_REV
14
GRANT_DENY
15
HARD_TYPES
16
RESTART
Page 20
Reference manual F
Description
Static data revision. Updated when static data is changed
Unique description for the resource block within a system, writable by
the host system operator.
Used by host system administrator to group blocks foe easy
identification of location.
Plant unit ID, for host system operator for sorting alarms
The target, actual and permitted modes for the block
TARGET
ACTUAL
PERMITTED
NORMAL
Error status associated with the hardware or software of the resource
block
0: Other
1: Block config error (not used)
2: Link configuration error
3: Simulate Active: Based on switch
4: Local override (not used)
5: Device Fail safe set
6: Device needs Maintenance Soon
7: Input failure (not used)
8: Output failure (not used)
State of the resource
1: Start restart
2: Initialization, actual mode = IMAN
3: Online linking
4: Online, actual mode = Auto
5: Standby
6: Failure
Read write test parameter for interoperability testing
Tag ID string identifying DD resource for info only
Manufacturing identification number, used by an interface device to
locate DD file for resource. Should show up as "Valve automation"
Manufacturers model number 0xD3A0 = Q Series – Pneumatic Valve Actuator 0xD3A0
Device Revision; Used to locate DD file set to: 4
Minimum compatible DD revision number associated with this device
Access control to host computer.
GRANT
DENY
The types of hardware available as channel numbers on this resource
Shows current status and allows a manual restart to be initiated,
implemented as method with warnings!
1 Run - Normal operation
2 Resource - Restart FF resource keep settings.
3 Defaults - Restart FF resource with default.
4 Processor - Restart FF Resource.
5 Actuator defaults - Restart control module with factory settings
6 Actuator processor - Restart control module, keep settings.
OUNDATION
Valid Range
0 to 65535
7 bit ASCII
1 to 255
OOS, AUTO
0 to F
9: Memory Failure (FF card)
10: Lost static data (FF card)
11: Lost NV data (FF card)
12: Readback check failed (not
used)
13: Device needs Maintenance
Now
14: Power-up (not used)
15: Out-of-Service
1 to 6
Not applicable Not applicable Not applicable
0x564144
4
1
Valid settings:
0 Program,
1 Tune,
2 Alarm,
3 Local
0 Scalar Input,
1 Scalar output,
2 Discrete
Input,
3 Discrete
Output
1 to 6
Fieldbus Control module
DOC.RM.BQC54.E Rev: 1
February, 2016
Initial Value
Permission
0
Read only
Spaces
Read / Write
0
Read / Write
0
Read / Write
AUTO
Read / Write
N/A
Read Only
OOS, AUTO
Read / Write
AUTO
Read / Write
N/A
Read Only
5
Read only
spaces
Read only
0x564144
Read only
0xD3A0
Read only
4
Read only
1
Read only
0x00
Read / Write
Read only
1
Read only