separate device it is possible after its assembly to attached it to the machine's frame
using 4 added screws for this purpose. In another case please made special fixing for
mounting the controller which can be used as a distance support as well (fig. 2, E element).
During electrical assembly there is a possibility of a electric shock thus all actions
should be made while electric power is off. For this purpose please turn off machine's
main electric switch!!!
All cable connections should be made using special wires with double insulation
oriented for use of the electric devices powered by 230V alternating current. Cables
should be rounded with diameter suitable into holes in the controller back casing
accordingly. Tips of the cables should be cleaned and special quill should be used or
tips should be covered by thin tin layer. Please follow this instructions very carefully
especially electric connections should be made according to provided instructions. It is
required for correct and failure-free controller operating.
Machine where the controller is mounted should be equipped in well working head saw
ending switchers and contactors of the up and down feeding should be protected to be
on at the same time !!!
Point - 2
In
power
TSS-8/001 needs to be mounted. Mounting is designed for well known and used holding bus
TSS-35. Please place the transformer as far as possible from other electrical elements ( e.g.
frequency changer, contactors, other transformers). It is important because of the
electromagnetic interference which may disturbing controller's electronics. Please connect to
the connections marked as PRI power supply of 230V. For power supply please choose this
phase of electric supply of the machine which is not connected to the any inductions coils,
contactors or inverters. 230V supply cables should be placed as far as it is possible form other
cables in the power cubicle. To the transformer's clips marked as SEC 12V please connect
wires which feed electronic plate of the controller. Analogically please place this wires as far
as it is possible from other power cables, especially from 230V which powered the
transformer. Length of the cables (12V) should be chosen accordingly to the place where the
controller is mounted.
Point – 3
Anti-disturbance choke CPZ (WX1P 224M 440V) added in the controller kit is designed to
protect from any other electromagnetic disturbance made by other electrical devices mounted
on the frame machine saw. Its correct mounting is decisive for correct controller operating.
Electric montage
CAUTION !
Power transformer TSS-8/001 assembly
cubicle
Choke CPZ mounting
www.selbit.pl