Download Print this page

TE Connectivity AMP NETCONNECT 1499119-1 Instruction Sheet

Undercarpet communications cabling system 4-pair unshielded twisted-pair (utp) cable

Advertisement

Quick Links

20.32 mm [.80 in.]
Internal Diameter
UNDERCARPET
COMMUNICATIONS
CABLE
1499119-1
0.76 m [250 ft]
1499119-5
30.5 m [100 ft]
1499539-1
0.76 m [250 ft]
1499539-5
30.5 m [100 ft]
Figure 1
1. INTRODUCTION
Undercarpet 4-pair UTP cables shown in Figure 1 are
used in undercarpet communications applications.
Dimensions in this instruction sheet are in metric
NOTE
units [with U.S. customary units in brackets].
Figures are not drawn to scale.
i
To obtain information on AMP NETCONNECT
products, call PRODUCT INFORMATION at the
number at the bottom of this page, or visit the
AMP NETCONNECT website at
www.ampnetconnect.com.
Reasons for reissue of this instruction sheet are
provided in Section 5, REVISION SUMMARY.
2. DESCRIPTION
The cable is provided on a reel that has a hole in the
center. The cable unwinds with the printed side of the
cable on top. The cable has a wing on each edge with
twisted-pair conductors inside a center rib.
3. INSTALLATION PROCEDURE
IMPORTANT: It is recommended that a qualified
technician install the undercarpet communications
cable.
AMP NETCONNECT logo is a trademark of TE Connectivity.
©2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
AMP NETCONNECT* Undercarpet
Communications Cabling System
4-Pair Unshielded Twisted-Pair (UTP) Cable
1499119-1 and -5 and 1499539-1 and -5
Reel
Printed Side
of Cable
Wings
Conductors
PERFORMANCE
LENGTH
LEVEL
Category 5e
Category 6
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
To avoid personal injury, ALWAYS DISCONNECT
DANGER
the electrical power before beginning work on any
circuit.
STOP
3.1. Planning
Before starting installation, understand the following:
— The communications cable should be installed after
the power cabling system is installed and just prior
to installing the carpet.
— Communications cable runs may cross the power
cable top shield; however, the crossing should not
occur where the power cable is tapped, spliced, or
folded.
— Except at crossings, the communications cable
should NOT run on top of the power cable top
shield or run closer than 152.4 mm [6 in.] to the
power cable top shield.
— DO NOT allow the communications cable to cross
other communications cable.
— If possible, routing of the communications cable
should be planned to avoid high traffic areas and
areas under desk chairs.
3.2. Transition Box, Communications Transition Block,
and Floor Fitting
Install the transition box, communications transition
block, and floor fitting according to the instructions
included with the product.
Instruction sheet included with product is:
NOTE
408-10336 — Surface Mount Wall Transition Box
i
408-10412 — Flush Mount Wall Transition Box
408-3368 — Category 5e Communications
Transition Block
408-10009 — Category 6 Communications
Transition Block
408-3179 — Low-Profile Floor Fitting
408-8843 — Multimedia Dual Data Kit
408-3129 — Conductor Direct Connecting
Receptacle (DCR) Kits
3.3. Prepare Floor Surface
Level or patch all uneven floor surfaces. Fill in and
smooth all holes and cracks, and remove all
projections, ensuring a smooth and continuous floor
surface. Seal all porous floors.
The communications cable must be installed onto a
CAUTION
clean and level floor surface.
!
3.4. Communications Cable
1. Cut a notch in the wall to allow the cable to radius
to the floor.
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
Instruction Sheet
408-3194
02 MAY 11 Rev K
1 of 3
LOC B

Advertisement

loading

Summary of Contents for TE Connectivity AMP NETCONNECT 1499119-1

  • Page 1 PRODUCT INFORMATION 1-800-522-6752 For latest revision and Regional Customer Service, *Trademark visit our website at www.te.com LOC B TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
  • Page 2 408-3194 2. Flex the wings of the cable while removing the Detail A cable from the reel. Orienting Communications Cable 3. From the distribution point (wall box or floor Printed Side fitting), lay the cable on the floor with the printed of Cable side of the cable facing up and the bow of the cable pointing up.
  • Page 3 408-3194 4. REPLACEMENT AND REPAIR Detail A The undercarpet communications cable is not Conductors repairable. DO NOT use any defective or damaged Communications Cable (Ref) cable. 5. REVISION SUMMARY Revisions to this instruction sheet include: • Changed company logo 25.4 mm [1.0 in.] •...

This manual is also suitable for: