5. Technical data

See motor and pump nameplates.

5.1 Sound pressure level, inlet pressure and temperatures

BMPX system
Sound pressure level Minimum/maximum inlet pressure

BMP hp feed pump

71.3 - 78.3 dB(A)
BM hp circulation
pump with VFD

X-Changer

* If the ambient temperature is higher than the values stated, please contact Grundfos.
** It is very important that the pump operates with the required discharge pressure to ensure proper lubrication of the pump.

6. Preparation

Before installation, the following checks should be made:
Check for transport damages
Make sure that the BMPX units have not been damaged
during transportation.
Type of system
Check that the type designation corresponds to order. See
nameplates.
Electricity supply
The motor and VFD voltage and frequency details given on the
nameplate should be compared with the actual electricity
supply available.
X-Changer
Check that all nuts are tightened.

7. Installation

The BMP hp feed pump and X-Changer are delivered separately
without any kind of base frame.
The installation must be carried out according to local regulations
and in such a way that proper and reliable operation can be
obtained.
7.1 BMP hp feed pump
The inlet port is marked with an "I" and the discharge port with an
"O".
Fig. 2
BMP hp feed pump and variable-frequency drive
70 dB(A)
Low pressure
(LP)
80 dB(A)
1/4 bar
Maximum liquid/
temperature*
0/4 bar
1/80 bar
High pressure
(HP)
–/80 bar
7.2 X-Changer
The inlet and discharge ports are shown in fig. 3.
High-pressure inlet
High-pressure discharge
Fig. 3
X-Changer
Minimum discharge
ambient
pressure**
40/40 °C
10 bar
40/40 °C
45/40 °C
Low-pressure discharge
Low-pressure inlet
5