Power Supply and Ground

Wire the power supply and the ground to the top terminal block,
and tighten the screws to a torque of between 0.5 and 0.6 N⋅m.
After wiring, confirm that wiring and screw tightening have been
done properly.
!
Caution
Cover the terminal blocks with the Terminal Block Protection
Covers.
2-4-1

Crimp Terminals and Cables

The terminal block uses M3 terminal screws. Use appropriate
crimp terminals for M3 screws, as shown below.
Forked
6.2 mm max.
Applicable wire size: Insulated wire of 1.31 to 1.65 mm
(AWG16 to AWG15)
2-4-2

Protective Conductor (Earth) Wiring

Wire the ground as shown in the following diagram.
Caution
!
Use an appropriate ground. An insufficient ground can affect
F150 operation or result in damage to F150 components.
• To avoid damage to the equipment, do not share the protective
• Keep the ground line as short as possible.
Class I
(with protective conductor
terminal)
2. If the field of vision is too small, use the F150-S1A Camera
with a normal CCTV lens and light.
conductor wiring with any other devices nor wire the protective
conductor terminal to the girder. Be sure to wire the protective
conductor of the equipment independently.
p. 17
Round
6.2 mm max.
Section
2-4
2
13