Mutual Interference; Power Supply - Omron Z4M-W10 Manual

Laser displacement sensor
Table of Contents

Advertisement

Z4M

MUTUAL INTERFERENCE

Separate each Sensor as specified in the following table when using more than two Sensors in close proximity to each other.
Installing direction
Z4M-W40
30 mm (1.18 in)
Z4M-W100
60 mm (2.36 in)
ENVIRONMENT
Install the Sensor in clean environment ensuring that the
filter on Sensor's front panel is kept free from oil and dust.
Do not use the Laser Displacement Sensor in a strong
electromagnetic field or in an environment where the
operation of the Sensor is subjected to the reflection of
intensive light (such as, light from a laser beam or an electric
arc welding machine).
The Laser Displacement Sensor cannot accurately detect
objects that are mirror-like, transparent, inclined or have an
extremely small reflection ratio (smaller than the Sensor's
sensing spot diameter).
WIRING
DANGER!
Do not wire the power supply cable for the Z4M Sensor in
the same conduit with high-voltage lines or power lines. The
result would be interference, damage, or malfunction.
A Z49-C1 Extension Cable can be connected to the Sensor
cable or to the amplifier cable. The total length of the Sensor
cables or amplifier cables must not exceed 10 m (32.91 ft.).
To extend the amplifier cable, use a shielded cable of the
same kind.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema
One East Commerce Drive
Schaumburg, IL 60173
1-800-55-OMRON
Cat. No. GC MSEN3

2/98
Specifications subject to change without notice.
30 mm (1.18 in)
60 mm (3.15 in)
Cleaning
If the filter is affected by oil or dust, clean it as follows:
1. Use a small air blowing device (like that used to clean
camera lenses) to remove dust particles from the surface.
Do not attempt to blow the dust away with your mouth.
2. Use a soft cloth (for lenses) moistened with alcohol to
remove the remaining dust. Do not use a scrubbing action
when cleaning; a scratch on the filter could result in the
Sensor malfunctioning.

POWER SUPPLY

Use an insulated transformer for the power supply of the
Z4M, as shown in the illustration provided.
Do not use an autotransformer. Use of an autotransformer
may cause the Z4M to malfunction.
Insulated transformer
Commercial
power supply
Z4M
60 mm (2.36 in)
80 mm (3.15 in)
+
Z4M
-
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
Printed in U.S.A.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z4m-w100

Table of Contents