Regular Inspections

7-2
Regular Inspections
To maintain the F150 in the best condition, perform the following
regularly.
• Lightly wipe off dirt with a soft cloth.
• Clean the Lens and indicators with a special lens cloth or air-
Caution
!
Turn OFF the power and take safety precautions before conduct-
ing inspections. Electrical shock can result from attempting
safety inspections with the power turned ON.
Caution
!
Do not use thinners or benzene. They will damage F150 compo-
nents.
brush.
Inspection point
Power supply
The voltage measured at
the power supply terminals
on the terminal block must
be 24 VDC
Ambient
The operating ambient
temperature
temperature inside the
cabinet must be between
0 and 50°C.
Ambient humidity
The operating ambient
humidity inside the cabinet
must be between 35% and
85%.
Installation
Each component must be
firmly secured.
Each cable connector must
be correctly inserted and
locked.
The Cameras must be
firmly secured.
The camera lens mounts
must be firmly secured.
Indicators
All indicators must light
when the power is turned
ON.
Details
Tools required
Circuit tester
+10%
/
.
–15%
Thermometer
Hygrometer
Phillips
screwdriver
---
Section
7-2
57