2 Enter the first number in the Address field beside Port 1 and the second number in the
Address field beside Port 2.
3 Click Submit to TA to save the changes back to the TA.

2.11.2 Caller ID

The caller ID (Caller Identification) information will display on the analog ports. Two caller
ID service types are supported by your TA.

2.11.2.1 Type 1: On-hook Caller ID Transmission

If the caller ID protocol uses DTMF (Dual Tone Multi-Frequency) signal, the caller ID
information includes the phone number and is sent prior to ringing.
If the caller ID protocol uses FSK (Frequency Shift Keying) signal, the phone number will be
sent during ringing.
The caller ID signaling type varies depending on the country.

Table 9 Caller ID signaling type

COUNTRY
Denmark
France
German
India
Ireland
Italy
Netherland
Norway
Portugal
Spain
Sweden
Switzerland
UK
Other (default)

2.11.2.2 Type 2: Off-hook Caller ID Transmission

The Type 2 service uses only FSK and shows call waiting caller ID. If the service is supported
and activated on your TA, the call waiting phone number is displayed when you are on the
phone.
Chapter 2 Using the Utility
COUNTRY CODE CALLER ID SIGNALING TYPE RINGING PATTERN
252
DTMF
219
FSK
237
FSK
214
DTMF
235
FSK
236
DTMF
253
DTMF
245
FSK
220
DTMF
213
DTMF
250
DTMF
251
DTMF
249
FSK
216
DTMF
Omni.Net Lite User's Guide
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
0.4 Sec On, 0.2 Sec OFF,
0.4 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
0.4 Sec On, 0.2 Sec OFF,
0.4 Sec On, 2 Sec OFF
1 Sec On, 2 Sec OFF
44