Table 14 AT Data Command Sets Requiring an "AT" Prefix
COMMAND
%D3=n
%Id=<phone
number> [/<sub-
address>]
%M1=n
%M2=n
%M3=n
%M4=n
%M5=n
%Od=<prefix digits>
%P0=n
%P1=n
Chapter 3 Using AT Commands
OPTION
DESCRIPTION
The number of retrying to re-dial the outgoing data call once TA
failed to establish the data call.
n=0: don't re-dial.
n=1~10: re-dial for n times until the call is established.
Create a list of the incoming call phone number via the data port.
d=0-4.
<phone number>: Enter up to 32 characters, including digits
from 0 to 9, *, #, hyphen ( -), comma (,) and (','). [','] will be
ignored.
<sub-address>: Enter up to 20 ASCII characters ranging from
"0-9"," a-z" and "A-Z".
Enable/Disable PAP to CHAP conversion.
n=0: Disable CHAP (default).
n=1: Enable CHAP.
Enable/Disable "Dynamic Bandwidth Allocation for Voice Call".
n=0: Disable.
n=1: Enable (default).
Set threshold of data loading to add one channel, the unit is
kbps.
n=0-64, the default is 35.
Set a threshold of data loading to drop one channel, the unit is
kbps.
n=0-64, the default is 25.
Persist time for monitoring threshold to add or drop one channel,
the unit is 5 seconds.
n=1-255, the default is 24.
Create a list of the outgoing call prefix digits for the data port.
d=0-2.
Set incoming call screen mode for the data port.
n=0: Accept all incoming calls (default).
n=1: Reject all incoming calls.
n=2: Only accept the calls from the phone number in the list (see
%Id=<phone number> [/<sub-address>]).
n=3: Only reject the calls from the phone number in the list (see
%Id=<phone number> [/<sub-address>]).
Set outgoing call screen mode for the data port.
n=0: No restriction (default).
n=1: Prohibit all outgoing calls.
n=2: Only accept the calls with the prefix in the pre-defined list
(see %Od=<prefix digits>).
n=3: Only reject the calls with the prefix in the pre-defined list
(see %Od=<prefix digits>).