J-frame motor operator

Advertisement

Quick Links

DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON
EQUIPMENT WHILE IT IS ENERGIZED. DEATH OR SEVERE PERSONAL
INJURY CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT.
ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING.
1
Effective Date 11/07
Instruction Leaflet for Series G
J - Frame Motor Operator
WARNING
CONTENTS:
Motor operator
Mounting screws (18 mm)
Mounting screws (16 mm)
Mounting screws (10 mm)
Springwashers
washers
IL01222026E
1x
2x
2x
4x
4x
4x

Advertisement

loading

Summary of Contents for Eaton Cutler-Hammer G Series

  • Page 1 IL01222026E Instruction Leaflet for Series G J - Frame Motor Operator WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH OR SEVERE PERSONAL INJURY CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING. CONTENTS: Motor operator Mounting screws (18 mm)
  • Page 2 Page 2 IL01222026E Mounting Screws Mounting Screws (16 mm length) (18 mm length) Support Assemble support onto the breaker with four Remove existing four screws from secondary mounting screws supplied. Torque to 0.44 to 0.6 cover of breaker. N.m or 4 to 5 in. lb. Mounting Screws (10 mm length) Springwashers,...
  • Page 3 Page 3 IL01222026E Opetating key Turn the key (Clockwise only) PUSH-TO TRIP Button Status Indication Slide knob Manual Operations • Move the slide knob to the MANUAL position to expose the manual operating shaft located under the slide knob. The control power supply is cut off automatically. •...
  • Page 4 Page 4 IL01222026E Motor Operator Wire Connection Diagram 208-240VAC/220-250VDC Application 24VDC Application 110-127VAC/110-125VDC Application 24VDC/48VDC Application Motor Operator Electrical Data Voltage Frequency Inrush Current 208-240 VAC 50/60 Hz 110-127 VAC 220-250 VDC 110-125 VDC 24 VDC 48 VDC 1) A minimum 150 VA power source is recommended. 2) Maximum rate of operation: 6 operations per minute.
  • Page 5 Page 5 IL01222026E Electrical Operation • Make sure the slide knob is located in the AUTO position. • Operating the OFF remote control switch will cause the breaker to go to its OFF position. • Operating the ON remote control switch will cause the breaker to go to its ON position. •...
  • Page 6 Page 6 IL01222026E Motor Operator Outline Dimensions – mm / [inch] Pittsburgh, PA U.S.A Effective 11/2007 IL...