Check there are no foreign bodies inside the fan or that can be drawn
into, or fall into fan.
Check the structure is complete and has no damage.
Check installation and area is safe and energise fan and start motor.
Check that the impeller and airfl ow direction is correct, check current
does not exceed fan equipment nameplate data.
After two hours of operation, check that all fi xings are tight and adjust
if necessary.

ELECTRIC MOTORS

For fans with S&P sourced/sub-supplier motors, the motor instruc-
tions will be included with the fan equipment for extra assistance to
Installer. Refer these for further motor guidance. Electrical connec-
tions are made in accordance with connection diagram in the motor
instructions and/or inside motor terminal box.
For smoke extraction installations in case of fi re, use high tempera-
ture cable type CR1-C1. The cable must always be protected against
UV radiation. Protect the cables from mechanical damage up to the
motor.
There must be no thermal protection device in the supply circuit in
smoke extraction mode.
In ventilation mode, the motor must be protected by a thermal mag-
neto protection device.
Many S&P fans are supplied with a cable gland for typical electrical
power cable connection, to assist installation. However, if Installer
uses a cable requiring a differing cable gland, this is to be supplied by
the Installer, no alternative is offered by S&P. The Installer is respon-
sible to ensure that cable, and cable gland, are suitable and safe for
application according to country regulations.
Ensure system operation is safe in event of power cut/power outage/
disruption to power supply. If ventilation is stopped due to disruption
to power supply, ensure no risk due to excessive temperature (electri-
cal heater). Care may be needed when restarting fan after disruption
to power supply.
Most motors are supplied with permanently greased or sealed for life
bearings and do not require re-lubrication. However, if motors with
re-greasing facility are supplied, then follow the instructions in the
specifi c motor Instruction manual and nameplate supplied.
Warning: Do not mix different types of grease.
Motors with speed control via Variable Speed Drive (VSD) Frequency
Inverter, should not be run in excess of nameplate speed. In general
applications, we recommend not to run at less than 20Hz and never
less than 20% of nameplate speed without reference to manufactu-
rer, since this may damage the motor.
If you are using cable longer than 20 meters between the drive and
the motor, add output sinusoidal fi lter.
If you are using cable longer than 50 meters between the drive and
the motor, add output EMC fi lter.

MAINTENANCE - REPAIRS

Maintenance/repairs must be carried out by competent personnel
and in accordance with applicable International, National and Local
regulations. Fan equipment should be electrically isolated and loc-
ked out before any work started.
Fan equipment should be regularly cleaned, frequency depending
upon service load and application, but no less than every 6 months.
Fan equipment for dust applications may require more frequent clea-
ning to ensure safe operation. Cleaning should include all areas whe-
re dust can accumulate in the fan equipment.
Special attention should be made to any unusual sounds, vibration or
temperature. If any problems are detected the fan equipment should
be stopped immediately and cause inspected. The impeller and bla-
des should be regularly checked for damage that could cause imba-
lance in the moving parts.

REPLACEMENT PARTS

Do not start working until all relevant safety procedures have been
read, understood and actioned correctly.
Ensure that personnel are competent for work required, spare parts
are correct for application, tools and materials to be used are availa-
ble and safe for environment.
Identify components, bolts, fi xings to be removed, and identify loca-
tion to ensure replaced in same location, this can be done by marking
with number/letter/colour to bolt fi xing and any associated spacing
material to identify location. This is especially important for motor
fi xings to supports, and impeller shaft fi xings to supports, where pac-
king/spacing/shim material is used to adjust motor/impeller shaft
center line, and hence fi nal impeller position.
GOOD PRACTICE, GOOD/BAD INSTALLATION ARRANGEMENT
Fans are designed and performance tested in accordance with stan-
dard duct arrangements. Thus they should be installed correctly
without any adverse installation effect. Typically fans should be
installed so that air entry is clear, unobstructed, non-turbulent and
discharge does not hinder airfl ow, since air turbulence adversely
affects impeller performance.

END OF LIFE DISPOSAL

Disposal must be carried out by competent personnel and in accor-
dance with applicable International, National and Local regulations.
Isolate fan equipment and any associated electrical equipment and
lock off. Remove electrical connections.
Disconnect fan equipment from duct connections and cover connec-
tions with plastic sheet to prevent exposure to any residue material in
fan equipment, and any contamination of ducts.
Dismantle and dispose in accordance with applicable National and In-
ternational laws and regulations, those parts whose service life has
expired.
In accordance with EC Directive and our responsibility for future gene-
rations, we are obliged to recycle all the materials we can. Therefore,
please deposit all waste material and packaging in their correspon-
ding recycling containers and hand in the replaced units to the nea-
rest handler of this type of waste product.
To clarify any questions regarding S&P products contact your local dis-
tributor. For its location and to obtain the EU Declaration of Conformity
and certifi ed technical data see our web site www.solerpalau.com.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cab-elCab-twin

Table of Contents