Code 51; Phase Adjust; Programming Of Flight Phases - GRAUPNER mc-24 PROFI-ROM Manual

Table of Contents

Advertisement

List of flight phase dependant menus for
helocopter models:
Code
Name
32
»Control adjust«
33
»Dual Rate/Expo«
34
»Channel 1 curve«
51*
»Phase adjust«*
53
»Phase trim«
58
»Non delayed channels«
71
»Heli mixer«
73
»Mix aktive /phase«
82
»Profi trim«
The page display mc-24/1 is relative only to the
MEGA-SOFT-ROM hand book.
*
Code 51 was changed from »Phase assignment« to
»Phase adjust«. The old Code 52 »Phase trim« has now the
number 53 in the PROFI-ROM and chan
(
Please note the details and change in page 26
All other menus are model dependant and not
programmable for each flight phase. Ch
all other menus
will affect all flight phases. If
nesecca
ry you can remove menus which can not
be changed in Code 13 » Suppress codes «
during programming of the flight phases in the
multi function list.
22
new functions

Code 51

Phase adjust

Programming of flight phases

Phase 1
Phase 2
Phase 3
Page
Phase 4
mc-24/1
here
49
18
54
-
58
-
In each model memory offers the mc-24 PROFI-
67
23
ROM the possibility of up to 8 independant
68
(27)
adjustments for different flight circumstances -
-
28
n
ormaly called "flight pha
77
-
96
-
Begin the programming for " flight phases " here in
102
-
Code 51 by allocating a name and maybe a timer
and delay time for change to the phase.
Next step is to select the neccessary "Phase
switches" in the ne
If a switch is alread
ged functions.
).
phases 1-8 you will see it indicated in the right
column:
anges in
Symbol
-
+
Hint:
Of help during programming of the various flight
phases is the command "Copy flight phase" in Code
12 »copy/erase«. First all parameters for a flight
phase are established and than copied into the next
flight phase where they can be modified to suit the
new flying mode.
0.0s
0.0s
0.0s
0.0s
Name
Flugph. Uhr Umsch. Z
SEL
SEL
SEL
ses".
w Code 52 » Phase assignme
y been allocated for any of the
Discription
No switch planned
Phase recall via switch
Marks the phase number allocate
the switch position
"Name": Press the
SEL
selector to choose a name from the list
-
for the required phases.
-
-
You can, apart from using the normal
eit
phase names also create your own
names in Code 91 » Basic settings «
( see further below ).
The sequence of phases 1 to 8 is not
critical and does not have to be continuos.
But you begin always with "phase 1" the
"normal phase" which is always active
when
• in Code 52 no phase switch is set
• no switch combinations exist
• all phase switches are in default
nt
«
position.
The phase name "normal" could therefo
be logical for "phase 1".
The names are program n
as ide
ntification only for the further
programming of flight phases and hence
they are displayed in all flight phase
d to
dependant menus and in the default
display.
A list of flight phase dependant m
shown further above.
-key and use the rotary
re
eutral and serve
enus is

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4831.6604831.6704831.6804831.690

Table of Contents