Discharge Setup Screen - GRAUPNER ULTRA DUO PLUS 50 Operating Manual

Hide thumbs Also See for ULTRA DUO PLUS 50:
Table of Contents

Advertisement

Available languages

Available languages

3. DISCHARGE MENU SCREEN
- - = - - - - - - -
DISCHARGE
D:00.0A 1.0V/CL 00°C
3. DISCHARGE MENU SCREEN
Warning: Deep discharging cells and too high discharge currents can destroy the
battery and can cause explosion and fire!
3-1. DSCH CURRENT
- Set wanted discharge currents. Check the battery instruction for the max.
discharge current.
3-2. DSCH CUTOFF
- Set discharge cutoff voltage per cell.
- Discharge is finished with smallest voltages with connecting the balancer cable the
balancing port of the charger.
3-3. CUT-TEMP
- Connect the temp sensor to battery, and discharge is finished when it reaches the
selected temp.
DISCHARGE SETUP<1/1>
DCHG CURRENT
DCHG CUTOFF _0.0V/C
CUT-TEMP.
MAX CAPACITY
MATCHED VOLT _0.00V
DISCHARGE SETUP<1/1>
DCHG CURRENT
DCHG CUTOFF _0.0V/C
CUT-TEMP.
MAX CAPACITY
MATCHED VOLT
If it is set to 1.0V/Cell and its battery cell is 6cells, the discharge is finished
at 6.0V.
For NiCd/NiMH batteries the cells should be never discharged lower as
1.1V/cell.
LiFe cells should be never discharged lower as 2.5V/cell and LiPo/LiIo cells
should be never discharge lower as 3.0V/cell for the highest possible life
time.
Deep Discharge can cause capacity loss and in the worst case it can
destroy the battery and cause explosion and fire.
Even if the cable is connected during discharging, discharge is not finished
with cell voltage.