6. Charge and discharge programs „Akku 1"
The various facilities of the charger are divided up into four program groups which you can select by
pressing the ENTER button. The sequence is shown in the flow chart below.
Note: If a battery is connected to the charger, it is not possible to switch to a different program group.
This is an intentional safety feature, designed to make it impossible to switch accidentally to a charge
program which is unsuitable for the battery in question when a charge process is actually in progress.
You can interrupt the charge process at any time by pressing the "MODE" button.
Ni-Cd battery programs: recharge, condition, balance, discharge to measure capacity or residual
capacity, or select cells.
Ni-MH battery programs: recharge, discharge to measure capacity or residual capacity, or select cells.
LiIo / LiPo battery programs: Charge, discharge to determine capacity, residual capacity, and cell
selection.
Lead-acid programs: recharge, discharge to measure capacity or residual capacity, trickle charge for
stand-by operation.
User settings: determine the basic functions of the charger, and set individual parameters within the
various charge programs.

7. Program flowchart

NiCd
NiCd
MODE
MODE
AUTOMATIC-
MANUAL-
program
program
ENTER
NiMH
NiMH
MODE
MODE
MANUAL-
AUTOMATIC-
program
program
ENTER
Lithium
Lithium
MODE
MODE
MANUAL-
discharge-
program
program
ENTER
Pb
Pb
MODE
MODE
AUTOMATIC-
MANUAL-
program
program
ENTER
Initial-
NiCd -
MODE
MODE
User-
∆ ∆ ∆ ∆ ∆ Peak
program
settings
NiCd
- 10 mV
NiMH
ENTER
Lithium
Pb
- 30 mV
Erase
Button click
MODE
- O F F
user
MODE
- ON
settings
Summer
- O F F
**erased**
- 10 sec.
- no limit
28
NiCd
NiCd
NiCd
MODE
MODE
discharge-
conditioning-
capacity test-
program
program
program
NiCd
balacing-
MODE
NiMH
NiMH
MODE
program
capacity test-
discharge-
program
program
NiCd
cycle count
MODE
Lithium
Lithium
MODE
MODE
type-
capacity test-
program
select
Pb
Pb
MODE
MODE
capacity test-
trickle-
discharge-
charge
program
program
NiMH -
NiCd / NiMH
NiCd / NiMH
MODE
MODE
MODE
∆ ∆ ∆ ∆ ∆ Peak
charge
termin delay
- 5 mV
.
.
.
AUS,
.
0...9 min.
10 ... 300 min.
- 25 mV
Initial
Car battery
MODE
MODE
MODE
current
cut-off
NiCd
0,1... 7A
NiCd
NiMH
0,1... 7A
NiMH
- 10,5 Volt
Lith.
0,1...9,9A
Pb
- 11.8 Volt
Pb
0,1... 7A
Akku2
0,05..0,5A
or automatic current
NiCd
AUTOMATIC-
program
ENTER
NiMH
AUTOMATIC-
program
ENTER
Lithium
MANUAL-
program
ENTER
Pb
AUTOMATIC-
program
ENTER
User
settings
ENTER
MODE
When the ULTRAMAT 25 is initially connected to a 12 V car battery, the unit runs through the informa-
MODE
tion routine which provides the user with a brief summary of the essential user settings. The charger's
screen displays the following information in sequence:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
G r a u p n e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
D U O
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
l o w
Pb
MODE
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
c u t
o f f
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i C d
d e l t a -
MODE
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
safety-
2 0 m V
timer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
S i c h e r h e i t s t i m e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 2 0
max.-
current
0,1... 7A
0,1... 7A
0,1... 7A
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i C d
a u t o m a t i c
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C : 2 . 5 A

8. Selecting the charge program group

The charge and setup facilities of the ULTRA DUO PLUS 30 are easy
to understand, and are logically divided into four program groups.
MODE
These cater for the various battery types: there is a separate pro-
gram group for each of the types Nickel-Cadmium, Nickel-Metal-
Hydride, Lithium-Ion / Lithium-Polymer and Pb (lead) batteries.
An additional program group contains the charger's basic setup
MODE
facilities.
Switching programs:
It is only possible to switch from one charge program group to the
next if no battery is connected to the charge outputs.
MODE
If a battery is connected to the unit, it is not possible to switch to
a different charge program group; you must first disconnect the
battery from the charger's output sockets.
MODE
It is only possible to switch from one charge program group to the
next when the charger is in AUTOMATIC mode. This means that
you must first press the MODE button repeatedly until the top line
of the screen displays the message "AUTOMATIC".
MODE
Press the ENTER button to switch program groups..

9. Using the charger for the first time.

The ULTRA DUO PLUS 30 informs you of its designation.
U L T R A
P L U S
3 0
2 sec.
The screen displays the voltage of the car battery at which the
v o l t a g e
charger breaks off the charge / discharge process due to in-
sufficient voltage. You can change this value in the program
=
1 1 . 8 V
group "User settings - low-voltage - cut-off".
2 sec.
The screen displays the trigger voltage for automatic charge
N i M H
termination which is set in the "User settings - Delta Peak volta-
p e a k
1 5 m V
ge" menu. The voltage is set separately for NiCd and NiMH
batteries, and the figure is stated in mV per cell.
2 sec.
The screen displays the maximum charge time for NiCd and
NiMH batteries which is set in the "User settings - safety timer"
m i n .
menu.
2 sec.
The screen displays the initial charge program which is set in
the program group "User settings - power-on settings", together
with the initial charge current.
l i m i t e d
The charger is now ready for use.
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

6416

Table of Contents