6. BALANCER MENU SCREEN
6-1. BALANCE <1/3> SCREEN
- This is to show each cell information which is connected to the balancing port of
the charger.
6-2. CELLS VOLTAGE <2/3>SCREEN
- Showing each cell voltage
6-3. BALANCE GRAPHIC
- CL, 0N : Showing the selected cell voltage
- A, M : Select Auto or Manual for Y axis of the graph
- Vy : Vy means a scale of voltage in Y axis.
- Vc : Vc means voltage of center position of Y axis.
BATTCELLS
0CELL - Connected cell number.
PACK VOLTS
0.000V – Overall cell voltage
AVG VOLTS
0.000V – Cell average voltage
GAP VOLTS
0.000V – Between max and min voltage
MAX NO. 0
0.000V - Max cell number and voltage
MIN NO.
0
0.000V - Min cell number and voltage
A(Auto) : If Auto is set, Vy and Vc are automatically set.
M(Manual) : If Manual is set, Vy and Vc can be manually set.