Discharge Page; Lipo, Liion, Life, Nicd, Nimh, Pb Battery Discharge Modes - GRAUPNER POLARON AC/DC SPORTS Operating Instructions Manual

Ac/dc sports 2 channels ac/dc charger
Table of Contents

Advertisement

◎ DISCHARGE PAGE

At the main mode, click the DCHG icon and you can move to the DISCHARGE mode.
USER NAME

LiPo, LiIon, LiFe, NiCd, NiMH, Pb battery discharge modes

- Voltage
: Final discharge voltage for each cell can be programmed
- Current
: Discharge current. - This parameter can be adjusted from 0.1 to 5.0 Amps, operating within
the maximum value of 30W
- Cut-Temp
: Cut-off temperature. - With an optional temperature sensor, a safety cut-off temperature
can be set, allowing the charging or discharging process to terminate automatically for battery
temperatures exceeding the preset temperature.
- Max Capacity
: The maximum capacity setting is used to terminate a discharge at battery capacities
exceeding a preset percentage value. Damaged, poorly balanced or improperly pro-
grammed battery parameters can result in an overdischarge.
On the main page, tap the DCHG icon to
start the discharge process.
Tapping the part in the red circle (image on the left) will
activate the parameters (blue), allowing the values to be
programmed into the data spots.
This page shows discharge setup for selecting
LiPo, Lilon, LiFe, NiCd, NiMH, Pb batteries
Discharge data configuration page. The configuration
Process is the same as charge data configuration.