Viewing The Firmware Version; Table 5-15 Leds For Firmware Update - Siemens SIMATIC S7-400 CP 440 Installation And Parameter Assignment

Point-to-point connection
Table of Contents

Advertisement

Configuring and Parameter Assignment the CP 440
5.6 Firmware updates
5.6.2

Viewing the Firmware Version

Viewing the Hardware and Firmware Version
You can view the current hardware and firmware version of the communication processor in
STEP 7 in the "Module Status" dialog. You can open this dialog by:
In SIMATIC Manager: File > Open > Project > HW Config > Station > Online > double-click
on the module of the communication processor.
LEDs
LEDs during the download of a firmware update:
Table 5-15
LEDs for firmware update
Status
INTF/EXTF
Firmware update in
on
progress
Firmware update
on
completed
CP 440 without
flashes (2 Hz)
module firmware
Hardware fault during
flashes (2 Hz)
firmware update
84
www.gkbpx.com
FAULT
TXD
RXD
on
on
on
off
off
off
on
off
off
off
flashes
flashes
(2 Hz)
(2 Hz)
Point-to-point connection CP 440 Installation and Parameter Assignment
Remark
To correct or avoid
errors
-
-
-
-
Module firmware
Reloading the firmware
deleted, firmware
update was canceled,
firmware update still
possible
Read/write operation
Switch power supply to
failed
module off and then on
again and reload the
firmware.
Check whether the
module is defective.