Siemens SIMATIC NET CP 443-5 Extended Manual

Siemens SIMATIC NET CP 443-5 Extended Manual

For use in a simatic s7-400 automation system

Advertisement

Quick Links

SIMATIC NET
S7-400 - PROFIBUS
CP 443-5 Extended
Manual
Manual Part B
11/2018
C79000-G8976-C162-09
___________________
Preface
___________________
Application and functions
___________________
Displays and mode selector
Installation and
___________________
commissioning
___________________
Notes on operation
___________________
Technical specifications
___________________
Approvals
___________________
References
1
2
3
4
5
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET CP 443-5 Extended

  • Page 1 ___________________ Preface ___________________ Application and functions ___________________ SIMATIC NET Displays and mode selector Installation and ___________________ commissioning S7-400 - PROFIBUS CP 443-5 Extended ___________________ Notes on operation ___________________ Technical specifications Manual ___________________ Approvals ___________________ References Manual Part B 11/2018 C79000-G8976-C162-09...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface ① LED displays ② Mode selector ③ PROFIBUS interface (9-pin D-sub socket) Product name This manual contains information on the following products: ● CP 443-5 Extended Article number: 6GK7443-5DX05-0XE0 Hardware product version: 1 Firmware version: V7.1.8 Communications processor for connection of SIMATIC S7-400 / S7-400H to PROFIBUS ●...
  • Page 4 You will find this manual on the Manual Collection DVD that ships with every CP or on the Internet at the following address: Link: (https://support.industry.siemens.com/cs/ww/de/view/1158693) ● Manual Part B - manual "S7 CPs for PROFIBUS - CP 443-5 Extended" ( this manual) Purpose of the manual This manual describes the properties of this device and shows application examples.
  • Page 5 Preface Current manual edition on the Internet You will also find the current version of this manual on the Internet pages of Siemens Industry Online Support: Link: (https://support.industry.siemens.com/cs/ww/en/ps/15679/man) Sources of information and other documentation You will find an overview of further reading and references in the Appendix of this manual.
  • Page 6 Siemens contact. Keep to the local regulations. You will find information on returning the product on the Internet pages of Siemens Industry Online Support: Link: (https://support.industry.siemens.com/cs/ww/en/view/109479891)
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 Application and functions ........................9 Application ..........................9 Communication services ......................9 Requirements for use......................12 1.3.1 Use with the current CPU types ....................12 1.3.2 Converting older systems ....................... 14 1.3.3 Project engineering ......................... 15 1.3.4 Programming ..........................
  • Page 8 Table of contents References ............................41 On configuring and using the CP ................... 41 On installing and commissioning the CP ................42 On programming ........................43 Index ..............................45 CP 443-5 Extended Manual, 11/2018, C79000-G8976-C162-09...
  • Page 9: Application And Functions

    Application and functions Application Automation system The CP 4435 Extended communications processor is designed for use in a SIMATIC S7400 (standard) and S7400H (faulttolerant system) automation system. The CP 443-5 Extended allows the S7400 / S7400H to be connected to a PROFIBUS fieldbus system. You can use the CP as a router for data records intended for field devices (for example DP slaves).
  • Page 10 DP Slaves complying with the PROFIBUS • • V0 and DPV1 standard DPV0 standard (DP slaves complying with the DPV1 standard can only be used with re- Siemens DP slaves • stricted functionality) Refer to the information about the required CPU Siemens DP slaves •...
  • Page 11 Application and functions 1.2 Communication services ● S7 communication and PG/OP communication – PG functions with uploading / downloading of FM modules, configuration / diagnostics and routing Note on routing: Dynamic switchover to alternative paths (for example if there is a problem on one of the possible transmission paths) is not supported.
  • Page 12: Requirements For Use

    Application and functions 1.3 Requirements for use Requirements for use The CP 4435 Extended described here is supported by all CPU operating systems in the versions listed in Tables 2-1 and 2-2 below. 1.3.1 Use with the current CPU types Configuration limits To use the CP type described here, the following limits and constraints apply within a rack: ●...
  • Page 13 Application and functions 1.3 Requirements for use ● DPV1 functionality ● CiR functionality (DP slave / DP slot, configurable extension) Note ET 200M devices that were assigned to SYNC/FREEZE groups with STEP 7, must not have modules of the type FM or CP inserted. Table 1- 1 Use with the current CPU types Order number of...
  • Page 14: Converting Older Systems

    Application and functions 1.3 Requirements for use 1.3.2 Converting older systems In conjunction with the CP 443-5 Extended V 7.0, the functionality supported by the discontinued CPU types listed in Table 2-2 is as follows: ● No DPV1 functionality ● No CiR functionality (DP slave, configurable extension) ●...
  • Page 15: Project Engineering

    Application and functions 1.3 Requirements for use Table 1- 3 Use with no longer available CPU types - part 2 Order number of Firmware Number of a = SYNC/FREEZE functionality the CPU: version AG_SEND or b = DP-V1 functionality AG_RECV calls at 6ES7...
  • Page 16: Programming

    You will find information on the current block versions and the current blocks to download from the Internet in our Customer Support at the following address: Link: (https://support.industry.siemens.com/cs/ww/en/ps/15677/pm) With older module types, this recommendation assumes that you are using the latest firmware version for the particular module type.
  • Page 17: Performance Data

    Application and functions 1.4 Performance data Program block Meaning START (SFB 19) / STOP (SFB 20) Run a warm restart / stop on a remote device. RESUME (SFB 21) Run a hot restart on a remote device. STATUS (SFB 22) Query the device status of a remote partner.
  • Page 18 Application and functions 1.4 Performance data Diagnostics requests As a DP master (class 1), the CP 4435 supports diagnostics requests of a DP master (class Note Default value for the startup parameter "Monitoring time for transfer of parameters to modules" In some situations, it is necessary to increase the default value for the startup parameter "Monitoring time for transfer of parameters to modules"...
  • Page 19: Characteristic Data Of Open Communications Services (Send/Receive Interface) Over Fdl Connections

    Application and functions 1.4 Performance data 1.4.3 Characteristic data of open communications services (SEND/RECEIVE interface) over FDL connections General characteristic data The characteristic data is important when operating FDL connections (specified, free layer 2 (SDA and SDN), broadcast, multicast): Table 1- 5 General characteristic data of open communications services Characteristic Explanation / values...
  • Page 20: Parallel Use Of Communications Services (Multiprotocol Mode)

    Application and functions 1.4 Performance data 1.4.5 Parallel use of communications services (multiprotocol mode) Performance Using the various available communications services at the same time affects communication performance. To illustrate the relationship between the connection types, the DP mode, and configured connections, the following values apply to the typical configurations: Connection type Number of connections...
  • Page 21: Time-Of-Day Synchronization

    Application and functions 1.4 Performance data Note Calling program blocks SFCs and SFBs For SFCs 11, 12, 13, 51, 55, 56, 57, 58, 59 and 103 as well as SFB 52 and 53, several calls are necessary. The time required to process the job depends on load, round-trip time and transmission speed.
  • Page 22: Data Record Routing

    Application and functions 1.4 Performance data 1.4.7 Data record routing A maximum of 11 connections can be established simultaneously to PA field devices at any one time. PDM can, however, use several connections to one PA field device (for more information, refer to the manual /6/ (Page 43)).
  • Page 23: Other Characteristics

    Application and functions 1.4 Performance data 1.4.9 Other characteristics Note on DP: The connected DP slaves can only be assigned to and serviced by one CPU. Note CiR functionality - no multicomputing If you use the CiR functionality, multicomputing is not possible. Memory reset on the CP WARNING Memory reset on the CP...
  • Page 24: Compatibility With Previous Product

    Application and functions 1.5 Compatibility with previous product Compatibility with previous product 1.5.1 Extended functionality compared with previous product Replacing a module The CP (6GK7443-5DX05-0XE0 and 6GK7443-5DX05-0XE1) described here with firmware version V7.0 can be used as a replacement for the following predecessors of the CP 443-5 Extended: ●...
  • Page 25: Replacing Older Modules / Module Replacement

    The document “Version History for the SIMATIC NET S7 CPs" contains information on the all the previously supplied PROFIBUS CPs for SIMATIC S7. An up-to-date version of this document is available for downloading on the Internet under the following entry ID: 9836605 (https://support.industry.siemens.com/cs/ww/en/view/67225941) 1.5.2 Replacing older modules / module replacement...
  • Page 26 Application and functions 1.5 Compatibility with previous product CP 443-5 Extended Manual, 11/2018, C79000-G8976-C162-09...
  • Page 27: Displays And Mode Selector

    Displays and mode selector LED display of the operating status of the CP The different combinations of the five LEDs on the front panel indicate the status of the CP: Table 2- 1 Legend - meaning of the symbols: Symbol Status ON (steady light) Flashing...
  • Page 28 Displays and mode selector INTF LED EXTF LED BUSF LED RUN LED STOP LED CP operating mode Firmware update completed. (As of firmware version V7.1.7) Download in RUN active / CiR • RUN with internal error (for example, bad • configuration data) PROFIBUS bus error RUN;...
  • Page 29: Installation And Commissioning

    Installation and commissioning Important notes on using the device Safety notices on the use of the device Note the following safety notices when setting up and operating the device and during all associated work such as installation, connecting up or replacing the device. 3.1.1 Notes on use in hazardous areas WARNING...
  • Page 30: Notes On Use In Hazardous Areas According To Atex / Iecex

    Notes on use in hazardous areas according to ATEX / IECEx WARNING DIN rail In the ATEX and IECEx area of application only the Siemens DIN rail 6ES5 710-8MA11 may be used to mount the modules. WARNING Requirements for the cabinet/enclosure To comply with EU Directive 94/9 (ATEX95), the enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529.
  • Page 31: Notes On Use In Hazardous Areas According To Ul Hazloc

    Installation and commissioning 3.2 Installation and commissioning 3.1.3 Notes on use in hazardous areas according to UL HazLoc WARNING EXPLOSION HAZARD Do not connect or disconnect while the circuit is live or unless the area is known to be free of ignitible concentrations.
  • Page 32 Installation and commissioning 3.2 Installation and commissioning Procedure Step Procedure / significance 1. Plug in the CP 443-5 Extended The CP 443-5 Extended can be operated in the following racks: Central rack CR2, CR3 • Universal rack UR1 UR2 or UR2H •...
  • Page 33: Notes On Operation

    Notes on operation General operation on PROFIBUS Disruptions with modified transmission speed If you modify the transmission speed when downloading the configuration, the CP 443-5 Extended sporadically remains in the "stopping" mode. In such cases, a memory reset of the S7 station is necessary. Follow the steps outlined below: 1.
  • Page 34: Display "Existing Channel Error" In The Diagnostics Interrupt Ob (Ob82)

    Other information available about the CP FAQs on the Internet You will find detailed information (FAQs) on using the PROFIBUS S7-CPs at the following Internet address (entry type: FAQ): Link: (https://support.industry.siemens.com/cs/ww/en/ps/15677/faq) CP 443-5 Extended Manual, 11/2018, C79000-G8976-C162-09...
  • Page 35: Technical Specifications

    Technical specifications General technical specifications Technical specifications Value Transmission speeds supported 9.6 kbps, 19.2 kbps, 45.45 kbps 93.75 kbps, 187.5 kbps, 500 kbps 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps Interfaces 1 x 9-pin D-sub female connector (RS-485) Connection to PROFIBUS •...
  • Page 36 Technical specifications CP 443-5 Extended Manual, 11/2018, C79000-G8976-C162-09...
  • Page 37: Approvals

    Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment ● IEC 61131-2 The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Division Process Industries and Drives Process Automation DE-76181 Karlsruhe...
  • Page 38 Approvals Link: (https://support.industry.siemens.com/cs/ww/en/ps/15679/cert) ● Entry type: "Certificates" ● Certificate type: "Declaration of conformity" WARNING Information on standards and approvals Before you put the device into operation, read the information on standards and approvals in Part A of this manual /3/ (Page 42).
  • Page 39 You should also note the information in the document "Use of subassemblies/modules in a Zone 2 Hazardous Area" that you will find on the Internet at the following address: Link: (https://support.industry.siemens.com/cs/ww/en/view/78381013) Until 19.04.2016 the CP meets the requirements of the EC Directive 2014/30/EU "Electromagnetic Compatibility”...
  • Page 40 SIMATIC NET products are regularly submitted to the relevant authorities and approval centers for approvals relating to specific markets and applications. If you require a list of the current approvals for individual devices, consult your Siemens contact or check the Internet pages of Siemens Industry Online Support: Link: (https://support.industry.siemens.com/cs/ww/en/ps/15679/cert)
  • Page 41: References

    References Where to find Siemens documentation ● Article numbers You will find the article numbers for the Siemens products of relevance here in the following catalogs: – SIMATIC NET - Industrial Communication / Industrial Identification, catalog IK PI – SIMATIC - Products for Totally Integrated Automation and Micro Automation, catalog...
  • Page 42: On Installing And Commissioning The Cp

    References B.2 On installing and commissioning the CP SIMATIC Fault-tolerant Systems S7-400H Manual Siemens AG Link: (https://support.industry.siemens.com/cs/ww/en/view/1186523) On installing and commissioning the CP SIMATIC S7 Automation System S7-400, M7-400 Siemens AG ● Installation: Installation manual Link: (https://support.industry.siemens.com/cs/ww/en/view/1117849) ● Module data: Reference manual Link: (https://support.industry.siemens.com/cs/ww/en/view/1117740)
  • Page 43: On Programming

    References B.3 On programming SIMATIC The Process Device Manager Manual Siemens AG Link: (https://support.industry.siemens.com/cs/ww/en/view/21407212) On programming SIMATIC NET Program blocks for SIMATIC NET S7 CPs Programming Manual Siemens AG Link: (https://support.industry.siemens.com/cs/ww/en/view/62543517) SIMATIC System and Standard Functions for S7-300/400 Programming manual Siemens AG Link: (https://support.industry.siemens.com/cs/ww/en/view/1214574)
  • Page 44 References B.3 On programming CP 443-5 Extended Manual, 11/2018, C79000-G8976-C162-09...
  • Page 45: Index

    Index DPV1, 23 DPV1 functionality, 13, 14 Automation system, 9 Electromagnetic compatibility, 35 Environmental conditions, 35 ET 200M I/O devices, 13 Backplane bus, 35 Battery backup, 11 Broadcast, 10 Bus fault, 33 Bus fault statistics, 33 FAQs on the Internet, 34 Bus parameter FDL connections, 10 Changing, 16...
  • Page 46 Index Mode selector, 28 STOP, 23, 28 Module replacement, 25 SYNC / FREEZE, 9, 12 MPI cable, 24 Synchronization interval, 21 Multicast, 10 System environment, 12 Multicomputing, 12, 14, 23 Technical specifications, 35 Open communications services, 10, 16 Time-of-day synchronization, 11 Operating mode, 27 Timeofday synchronization frames, Order number, 12...

Table of Contents