Haier QVM7167 Installation Instructions Manual page 22

Range microwave oven
Hide thumbs Also See for QVM7167:
Table of Contents

Advertisement

Available languages

Available languages

OUTSIDE BACK EXHAUST
C
INSTALLATION OVERVIEW
C1. Prepare Rear Wall
C2. Attach Mounting Plate to Wall
C3. Prepare Top Cabinet
C4. Adjust Blower
C5. Mount the Microwave Oven
PREPARING THE REAR WALL FOR
C1
OUTSIDE BACK EXHAUST
You need to cut an opening in the rear wall for outside
exhaust.
• Read the instructions on the REAR WALL
TEMPLATE.
• Tape it to the rear wall, lining up with the holes
previously drilled for holes A and B in the mounting
plate.
• Cut the opening, following the instructions of the
REAR WALL TEMPLATE.
22
Installation Instructions
(Horizontal Duct)
3/8" TO EDGE
OPTION 2
STEP 1:
OPTION 1
12"
mark is made by using the stampled slot in bracket.
Installer uses bracket to make 2 marks. First
Second mark is made on the ouside edge of bracket.
NOTE: IT IS VERY IMPORTANT TO
READ AND FOLLOW THE DIRECTIONS
F. CUT OUT FOR HORIZONTAL
IN THE INSTALLATION INSTRUCTIONS
BEFORE PROCEEDING WITH THIS
REAR WALL TEMPLATE.
4"
OUTSIDE EXHAUST
Horizontal line
This Rear Wall Template serves to position the bottom
mounting plate and to locate the horizontal exhaust
outlet.
CUT HOLE THROUGH REAR WALL FOR EXHAUST ADAPTOR
1. Use a level to check that the template is positioned
accurately.
Make a mark
here,
Make a mark here, along
STEP 4:
2. Locate and mark at least one stud on the left or
even with
bottom of
inside bottom of the
stamped slot provided.
right side of the centerline.
slot
stamped
NOTE:
It is important to use at least one wood
screw mounted firmly in a stud to support the weight
of the microwave. Mark two additional, evenly spaced
STEP 2:
the cabinets and makes 2 more marks. Marks are the
Installer moves bracket to the other side of
locations for the supplied toggle bolts.
same as STEP 1, just opposite side.
3. Drill holes in the marked locations. Where there is
a stud, drill a 3/16" hole for wood screws. For holes
that do not line up with a stud, drill 5/8" holes for
toggle bolts.
NOTE::
D O NOT INSTALL THE MOUNTING PLATE
AT THIS TIME.
4. Remove the template from the rear wall.
5. Review the Installation Instruction book for your
installation situation.
Make a
inside bottom of the
Make a mark here, along
mark here,
even with
Darle vuelta a la hoja para consultar la
(same as Step 1).
stamped slot provided
stamped
bottom of
versión en Español.
slot
CAUTION - IF EXHAUST ADAPTOR IS POSITIONED OUTSIDE
RECOMMENDED DIMENSION, GREASE-LADEN AIR WILL
DISCHARGE INTO HOUSE STRUCTURE
NOTES:
30" MINIMUM WIDTH REQUIRED
- 13" Max Cabinet Depth
Locate and mark holes to align with holes in the
- 15" deep cabinets require additional steps using
an additional installation kit: JX36BUMP
mounting plate.
IMPORTANT:
REAR WALL TEMPLATE
LOCATE AT LEAST ONE STUD ON EITHER SIDE OF
THE CENTERLINE.
MARK THE LOCATION FOR 2 ADDITIONAL, EVENLY
SPACED TOGGLE BOLTS IN THE MOUNTING PLATE
AREA.
C
Trim the rear wall template along the dotted line.
A
C
D
B
ATTACH THE MOUNTING PLATE
C2
TO THE WALL
Attach the plate to the wall using toggle bolts and wood
screw. At least one wood screw must be used to attach the
plate to a wall stud.
1
Remove the toggle wings from the bolts.
Insert the bolts into the mounting plate through
2
the holes designated to go into drywall and reattach the
toggle wings to
3 4
To use toggle bolts:
Spacing for Toggles More
Than Wall Thickness
Toggle Wings
Mounting
Toggle
Plate
Bolt
Wall
Insert the toggle wings into the holes in the wall to
3
mount the plate and place the mounting plate against
the wall.
Be careful to avoid pinching fingers
CAUTION
between the back of the mounting
plate and the wall.
4
Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.
Bolt
End
31-7000069 Rev. 1

Advertisement

Table of Contents
loading

Table of Contents