4.4. Removal of the top cover
3
2
4.5. Replacing the magnesium anodes and electric heater
© All rights reserved - Galmet Sp. z o.o. Sp. K
2
1. Remove the controller(according to p. 4.3.)
2. Unscrew 3 screws from the cover
3. Lift the cover up
2
2
3
Basic 200
Installation and operation manual of the Basic heat pump
4. Technical description
1
1. Remove the front panel – unscrew
6 screws
2. Unscrew the anodes from the tank
3. Unscrew the electric heater from
the tank
35