Galmet Easy Air Basic 2 GT Operation & Installation Manual

Air-to-water heat pump warranty card

Advertisement

Operation & Installation Manual
WARRANTY CARD
EASY AIR BASIC 2 GT
Air-To-Water Heat Pump
In operating mode the heat pump generates domestic hot water at a maximum
temperature of 50ºC
- 1 -
OPERATION MANUAL AND WARRANTY CARD
"Galmet Sp. z o.o." Sp.K.

Advertisement

Table of Contents
loading

Summary of Contents for Galmet Easy Air Basic 2 GT

  • Page 1 Operation & Installation Manual WARRANTY CARD EASY AIR BASIC 2 GT Air-To-Water Heat Pump In operating mode the heat pump generates domestic hot water at a maximum temperature of 50ºC - 1 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.” Sp.K.
  • Page 2 17. Device inspection card ....................... 15 18. Declaration of Conformity ....................15 19. Notes ........................... 17 20. Warranty Terms and Conditions ..................18 21. Warranty card ........................19 - 2 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 3: Use And Operation

    1. Use and operation The EASY AIR BASIC 2 GT heat pump is an air-to-water heat pump making it possible to provide domestic hot water maximum for a 6-person family. The maximum temperature of the domestic hot water generated by the heat pump is 50°C. However, for energy-saving reasons it is recommended not to set the temperature of domestic hot water above 45 °C, as it will result in raising the costs of using the heat pump and will...
  • Page 4: Proper Operation

    15ºC 4.5 h + 10ºC 15ºC 5.5 h 15ºC + 7ºC 6.0 h Coil Each heat pump is equipped with one coil used to connect additional heat sources. - 4 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 5: Heat Pump Specifications

    3. The device should be carried in its original packaging. 4. When lifting the device always use protectors to avoid damage to tapes and ensure the device weight is properly balanced. - 5 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 6: Schematic Diagrams Of The Heat Pump

    9. Schematic diagrams of the heat pump General view Heat pump components Fig. 1 Heat pump view 9.1. General dimensions 45° Fig. 2 Heat pump dimensions - 6 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 7: Transport Method

    Max. duct length 5 m Air outlet - rated air flow Air inlet - rated air flow 300 m3/h 300 m3/h   160mm 160mm GALMET Fig. 4 Air duct connection - 7 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 8: Installing The Heat Pump Indoors

    Coil return Cold water Fig. 6 Heat pump positioning inside the boiler room The minimum length between the suction duct and cold air outlet should be 1.5 m !! - 8 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 9: Heat Pump Air Supply From The Outside And Air Discharge Into Another Room

    Domestic hot water room, garage Coil supply Circulation Sensor Coil return Cold water Fig. 8 Air supply from the boiler room and discharge into another room - 9 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 10: Supplying And Discharging Air From The Heat Pump Outdoors

    Coil supply Circulation Sensor Coil return Cold water Fig. 9 Air supply and discharge outdoors 11. Description of heat pump connections Fig. 10 Dimensions of connection fitting layout - 10 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 11: Schematic Diagram Of The Heat Pump Hydraulic System

    12. Schematic diagram of the heat pump hydraulic system Fig. 11 Schematic diagram of the heat pump hydraulic system 13. Connections Fig. 12 Heat pump connections - 11 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 12: Schematic Diagram Of The Device Hydraulic System

    14. Schematic diagram of the device hydraulic system Fig. 13 Schematic diagram of the heat pump - 12 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 13: Schematic Diagram Of The Device Electrical Wiring

    The heat pump should be provided with a current-differential and overcurrent protections (fuses); the rate of overcurrent protections depending on the device electrical power is presented in the table below. Protection Type Heat Pump Type EasyAir Basic 2GT - 13 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 14 A proper recycling of electrical and electronic devices helps to protect the natural environment and prevents negative impact on human health. - 14 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 15: Troubleshooting Guide

    Pressure in Servicing Stamp and heating circuit operations signature of fitter First start-up Inspection after 12 months Inspection after 24 months Inspection after 36 months 18. Declaration of Conformity - 15 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 16: Declaration Of Conformity

    DECLARATION OF CONFORMITY "Galmet Sp. z o.o.” Sp. K. (Company name) UL. RACIBORSKA 36 48-100 GŁUBCZYCE declares that the following product: EasyAir Basic 2GT Air-To-Water Heat Pump this declaration applies to is compliant with the following Directives: - Pressure Equipment Directive (PED): 97/23/EC...
  • Page 17: Notes

    19. Notes - 17 - OPERATION MANUAL AND WARRANTY CARD "Galmet Sp. z o.o.”...
  • Page 18: Warranty Terms And Conditions

    14. When the Buyer makes it impossible to carry out a warranty repair twice, despite the warrantor’s readiness to carry it out, it is considered that the Buyer gives up the warranty claim. "Galmet Sp. z o.o.” Sp. K., reserves the right to introduce changes in the specifications or models to improve devices without prior notice.