1.5. Controller description

The ST-53.2 controller is used to operate the Basic heat pump. The purpose of this device is to control the operation of the compressor, pump, fan, heater, and
an additional heat source pump. A detailed description of the controller and its operating principles are contained in a separate instruction.

1.6. Technical specification

Specification
Catalogue number
Thermal power
Working temperature range
Number of coils
Surface of additional coils
COP
Maximum DHW temperature
Maximum water temperature (heat pump + heater)
Dimensions (height x diameter)
Weight
Acoustic power (according to the EN 12102 norm)
Acoustic pressure (at a distance of 2 meters)
Nominal air flow
Maximum length of air ducts
Refrigerant
Amount of refrigerant
Heat pump's power consumption
Electric heater power
Total heating power (heat pump + heater)
Supply voltage and device supply frequency
Maximum energy uptake
Electric protection
Water intake profile (in compliance with EN-16147)
Q
elec
Maximum volume of mixed water(V
reference temperature (ɵ
)
1
WH
Maximum volume of mixed water(V
reference temperature (ɵ
)
1
WH
Suggested electrical protection
Connection fittings
Condensate connection
Compressor
Heater's maximum working pressure
Maximum coil pressure
Heater's maximum working temperature
Coil's maximum working temperature
Tank type
Tank diameter
Tank height
EN-16147 A15W10-55
1
EN-16147 A20W10-55
2
© All rights reserved - Galmet Sp. z o.o. Sp. K
Unit
-
kW
°C
-
m
2
-
°C
°C
mm
kg
dB
dB
m
/h
3
m
-
kg
kW
1
kW
kW
V/Hz
A
-
-
kWh
)
l
1
40
°C
)
l
1
40
°C
-
-
mm
-
MPa
MPa
°C
°C
-
mm
mm
Basic 200
09-353102
09-355102
2
+7/+35
1
1
1
1
3,5
1
3,8
2
55
75
1500 x 670
120
130
57
46
365
10
R134a
1,2
0,4
2
4
230/50
10,7
IP22
L
3,1
197
50,27
199
50,07
C16
1" (circulation 3/4)
1" (circulation 3/4)
12
rotary
1
1,6
100
110
SGW(S)
SGW(S)
660
660
1140
1360
Installation and operation manual of the Basic heat pump
1. Proper operation
Basic 270
09-355202
2
+7/+35
2
1 / 0,7
3,1
1
3,4
2
55
75
1730 x 670
150
56
45
314
10
R134a
1,2
0,4
2
4
230/50
10,7
IP22
XL
5,7
346
54,68
347
55,01
C16
1" (circulation 3/4)
12
rotary
1
1,6
100
110
SGW(S)B
660
1360
Basic 300
09-356100
2
-7/+35
1
1
2,4
1
2,7
2
55
75
1900 x 670
135
62
51
328
10
R134a
1,2
0,4
2
4
230/50
10,6
IP22
XL
7,1
392
52,50
392
52,65
C16
12
rotary
1
1,6
100
110
SGW(S)
660
1460