Repair; Grounding; Pressure Relief Procedure - Graco A Series Instructions And Parts List

Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Repair

Repair
To service the pump assembly, see manual
311211.
To service the air motor, see manual 311238.
To service the hydraulic motor, see manual
308330.

Grounding

The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Pump: Use the ground screw (Z) and lockwasher on the
motor to attach ground wire 244524 (Y). Tighten the
screw securely. Connect the other end of the ground
wire to a true earth ground. See F
Z
F
. 1
IG
Air and fluid hoses: use only electrically conductive
hoses with a maximum of 500 ft. (150 m) combined
hose length to ensure grounding continuity. Check the
electrical resistance of hoses. If total resistance to
ground exceeds 29 megohms, replace hose immedi-
ately.
Air compressor: follow manufacturer's recommenda-
tions.
6
. 1.
IG
Y
TI8250a
Hydraulic power supply: follow manufacturer's recom-
mendations.
Surge tank: use a ground wire and clamp.
Spray gun: ground through a connection to a properly
grounded fluid hose and pump.
Fluid supply container: follow local code.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the spray gun
firmly to the side of a grounded metal pail, then trigger
the gun.

Pressure Relief Procedure

1. Engage trigger lock.
2. Air-Powered Pumps only: Close the bleed-type
master air valve.
Hydraulic-Powered Pumps only: Close the hydraulic
supply line valve first, then the return line valve.
3. Disengage the trigger lock.
4. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun to relieve pressure.
5. Engage the trigger lock.
6. Open all fluid drain valves in the system, having a
waste container ready to catch drainage. Leave
drain valve(s) open until you are ready to spray
again.
7. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after follow-
ing the steps above, VERY SLOWLY loosen tip
311690M

Advertisement

Table of Contents
loading

Table of Contents